English
Language : 

CSEX-X-OL Datasheet, PDF (1/2 Pages) CUI INC – current sensor
Features
· RoHS Compliant
· Low insertion losses
· Easy mounting
· Small size and space saving
· High immunity to external interference
CSEX-X-OL Series
current sensor
Date: 5/29/07
Unit: mm
Page No: 1 / 2
Models
Model
CSE100-300-OL
Notes:
1. AT = 25°C.
2. RL = 10 KΩ
Output
Voltage1,2
Nominal
R.M.S
Current1
100 mV ±15% @±IPN 100 A
Current
Measuring
Range1
0 ~ ±300
Supply
Voltage1
4 V ±5%
Current
Offset
Consumption1 Voltage1
±5.85 mA ±7 mV @IP=0
Operating Performance
Thermal drift of VO
Thermal drift of VOUT
Response time
Linearity
Accuracy
Hysteresis offset voltage
Isolation voltage
Frequency bandwidth
±0.5 mV/°C
0.04%/°C
5µs
2% @0~±IPN
±15% @IPN
±10 mV @±IPN→0
3 KV @ 50/60 Hz for 1 minute
0 ~ 50 KHz
General Data
Operating temperature
Storage temperature
Mass
-25 ~ +85°C
-40 ~ +100°C
6.5g
Setup Diagram
Current direction
POWER SUPPLY
-
+
1
4
VOLTMETER
-
Phone: 800.275.4899 Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave. Tualatin, OR 97062