English
Language : 

VCT2001A Datasheet, PDF (5/5 Pages) CTS Corporation – HCMOS Output-Dual Input Clock Generator
PRELIMINARY
Module Data Sheet: VCT2001A 77.760 MHz
Application: HCMOS Output-Dual Input Clock Generator
4.0 STANDARD ENVIRONMENTAL LIMITS
This product is capable of operating within the following environmental conditions:
4.1 Operating Temperature
4.2 Storage Temperature
4.3 Humidity (non- Condensing)
4.4 Atmospheric Pressure
4.5 Vibration
4.6 Shock
0 to +70 °C.
-40 to +85°C.
95% Relative humidity max @ 40°C.
730 to 780 mm Hg.
10 to 60 Hz with double amplitude of
1.52mm max.
(1/2 hour in each of 3 perpendicular planes).
1/2 sine pulse, 7000G, with pulse width
0.3mSec.
(1 shock in each of 6 directions of 3
perpendicular planes).
5.0 MAXIMUM SOLDERING PROFILE
Temperature 110 to150 °C >183°C
Time
6min
2.5min
>235°C
0.25min
240°C
Max temperature
6.0 ALARM SITUATIONS
Loss of Reference Situation
Page 5
Loss of Lock Situation
Rev. “4” 3/28/03