118 Datasheet, PDF (1/4 Pages) CTS Corporation – 1”x1” Stratum 3E OCXO
Model 118
♦Frequency Stability to Stratum 3E of GR-1244
♦Low Phase Jitter: <1pSec
♦+3.3Vdc or +5.0Vdc Operation
♦Precision Low Aging “SC” Cut Crystal
♦Through-Hole or Surface Mount Configuration
♦RoHS Compliant
1”x1” Stratum 3E OCXO
Electrical Characteristics
Parameter
Sym
Conditions
Power Requirements
Power Supply
Turn-On Power
Steady State Power
Warm-Up Time
Frequency Stabilities
Vcc
Pmax
Pss
Twu
± 5%
± 5%
Vcc = Max., Std. Load
Vcc = Max, Std. Load @ +25°C
To meet full spec @ +25°C
Center Frequency
fnom
Initial Tolerance
Frequency vs. Temperature
Frequency vs. Voltage
Frequency vs Time (Aging)
24 Hour Holdover Stability
Total Free-Running
Accuracy
Electrical Freq Adjust Option
Waveform: HCMOS Output
Symmetry
Amplitude
Rise/Fall Times
Load
Sub-Harmonics
Phase Noise
fcal
∆f/∆Temp
∆f/∆Vcc
∆f/∆Time
∆f/24Hr
∆f/Life
∆f/Vc
Sym
Vo
tr, tf
RL
Ta = +25°C (At time of Shipment)
Over Operating Temperature
Vcc ± 5%
per Day
20 years
Inclusive of Temperature, Supply
Variation and 24 hours Aging
All Conditions for 20 years
(Reference to fnom)
Vc = 0 V to Vcc
@ 50% Level
Logic “1”
Logic “0”
20% to 80%
Output to Ground
Offset = 1 Hz
10 Hz
100 Hz
1 KHz
10 KHz
Min
3.135
4.75
10.0
±0.75
40
0.9Vcc
Typical
3.30
5.0
3.5
1.5
10, 12.8, 16.384,
19.44, 20, 25, 26
± 0.2
±6
±1
±1
±8
50
4
10KΩ // 15pF
-70
-105
-130
-140
-142
Max
3.465
5.25
4.0
15
38.88
± 0.5
±8
± 1.5
± 10
± 2.1
60
0.1Vcc
7
-25
-60
-95
-125
-130
-135
Unit
Vdc
Vdc
W
W
minutes
MHz
ppm
ppb
ppb
ppb
ppm
ppb
ppm
ppm
%
V
V
nSec
dBc
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
♦♦♦ CTS ♦ 171 Covington Dr. ♦ Bloomingdale, IL 60108 ♦ 800-757-6686 ♦ www.ctscorp.com ♦♦♦
REVISION X3
Page 1 of 4