English
Language : 

CTDD2010DLF-SU1K-1 Datasheet, PDF (1/2 Pages) Central Technologies – DC/DC Converters
DC/DC Converters
ctparts.com
CTDD2010DLF-SU1K-1 Series
SPECIFICATIONS
Fixed Input Isolated & Unregulated
1W Output, Single Output
Part
Number
CTDD2010DLF-0303-SU1K-1
Vin
Nom.
(VDC)
3.3
Input Range
(VDC)
3.0-3.6
Iout Iout
Effi.
Vout Max. Min.
Typ.
(VDC) (mA) (mA)
(%)
3.3
300
30
72
CTDD2010DLF-0305-SU1K-1 3.3
3.0-3.6
5
200
20
73
RoHS
Compliant
Not shown at actual size.
CTDD2010DLF-0503-SU1K-1 5
CTDD2010DLF-0505-SU1K-1 5
CTDD2010DLF-0509-SU1K-1 5
CTDD2010DLF-0512-SU1K-1 5
CTDD2010DLF-0515-SU1K-1 5
CTDD2010DLF-1203-SU1K-1 12
CTDD2010DLF-1205-SU1K-1 12
CTDD2010DLF-1209-SU1K-1 12
CTDD2010DLF-1212-SU1K-1 12
CTDD2010DLF-1215-SU1K-1 12
CTDD2010DLF-2403-SU1K-1 24
CTDD2010DLF-2405-SU1K-1 24
CTDD2010DLF-2409-SU1K-1 24
CTDD2010DLF-2412-SU1K-1 24
CTDD2010DLF-2415-SU1K-1 24
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
10.8-13.2
10.8-13.2
21.6-26.4
21.6-26.4
21.6-26.4
21.6-26.4
21.6-26.4
3.3
300
30
74
5
200
20
78
9
111
12
79
12
83
9
80
15
67
7
78
3.3
300
30
75
5
200
20
78
9
111
12
80
12
83
9
81
15
67
7
79
3.3
300
30
76
5
200
20
79
9
111
12
80
12
83
9
81
15
67
7
79
FEATURES
Efficiency: To 81%
Temperature Range: -40°C to 85°C
Isolation: 1KVDC
Package: UL94-V0
Miscellaneous: Single Output. Extremely slim with 4.5mm height.
Fixed input voltage. No heat sink required. No external component
required. Industry standard pinout. Compatible with “BB” DCP01
series. Unregulated output voltage. Custom service available.
Samples available.
CHARACTERISTICS
Short Circuit Protection: 1 second
Temperature Rise at Full Load: 25°C Max. 15°C Typ.
Cooling: Free air convection
Operating Temperature Range: -40°C to +85°C
Storage Temperature Range: -55°C to +125°C
Lead Temperature: 300°C (1.5mm from case for 10 seconds)
Storage Humidity Range: < 95%
Case Material: Plastic (UL94-V0)
MTBF: >3,500,000 hours
Miscellaneous: RoHS Compliant.
Item
Isolation Voltage
Isolation Resistance
ISOLATION SPECIFICATIONS
Test Condition
Tested for 1 minute
Test at 500VDC
MIN
TYP
1000
1000
MAX
Units
VDC
MΩ
OUTPUT SPECIFICATIONS
Item
Output Power
Line regulation
Load regulation
Output voltage accuracy
Temperature drift
Output ripple & noise
Switching frequency
Test Condition
For Vin change of 1%
10% to 100% full load
See tolerance envelope graph
100% full load
20MHz bandwidth
Full load, nominal input
MIN
TYP
MAX
Units
0.1
1
W
1.2
%
10
15
%
0.03
%/°C
50
75
mVp-p
100
KHz
Note:
1. All specifications measured at TA=25°C, humidity<75%, nominal input voltage and rated output load
unless otherwise specified.
TYPICAL CHARACTERISTICS
Tolerance Envelope Graph
+10%
+5%
Nominal
Voltage
Typical Load Line
+2.5%
-2.5%
-7.5%
10%
50%
100%
Output Current(%)
Temperature Derating Graph
120
100
80
60
Safe Operating Area
40
20
0
-40 0 40 80 120
Ambient Temperature(°C)
CENTRAL
01.11.07
Manufacturer of Inductors, Chokes, Coils, Beads, Transformers & Toroids
800-684-5322 Inside US
949-453-1811 Outside US
Copyright © 2006 by CT Magnetics, DBA Central Technologies. All rights reserved.
CT Magnetics reserves the right to make improvements or change specifications without notice