English
Language : 

GPL1272 Datasheet, PDF (1/2 Pages) CSB Battery Co., Ltd. – general purpose battery up to 8 years
Powered by
GPL 1272 12V 7.2Ah
Specification
GPL 1272 is a general purpose battery up to 8 years in standby
service or more than 260 cycles at 100% discharge in cycle
service . As with all CSB batteries, all are rechargeable , highly
efficient , leak proof and maintenance free.
Cells Per Unit
6
Voltage Per Unit
12
Capacity
7.2Ah @ 20hr-rate to 1.75V per cell @25 (77 )
Weight
Approx. 2.6 kg(5.73 lbs)
Maximum Discharge Current
100A/130A(5sec)
Internal Resistance
Approx. 21 m
Operating Temperature Range
Discharge: -15 ~50 ( 5 ~122 )
Charge: -15 ~40 ( 5 ~104 )
Nominal Operating Temperature Range
Storage: -15 ~40 ( 5 ~104 )
25 3 (77 5 )
Float Charging Voltage
13.5 to 13.8 VDC/unit Average at 25 (77 )
Recommended Maximum Charging
2.16A
Current Limit
Equalization and Cycle Service
14.4 to 15.0 VDC/unit Average at 25 (77 )
Self Discharge
CSB Batteries can be stored for more than 6 months at
25 (77 ) . Please charge batteries before using . For
higher temperatures the time interval will be shorter.
Terminal
Container Material
F1/F2-Faston Tab187/250
ABS(UL 94-HB/File E50263)*Flammability resistance of
(UL 94-V0/File E88637) can be available upon request.
CSB-manufactured
VRLA batteries are UL-
recognized components
under UL924 and UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
Dimensions :
Unit: mm (inch)
Overall Height (H)
100±1 (3.94±0.04)
Container height (h)
94±1 (3.7±0.04)
Length (L)
151±2 (5.94±0.08)
Width (W)
65±1 (2.56±0.04)
F.V/Time
1.60V
1.67V
1.70V
1.75V
1.80V
1.85V
F.V/Time
1.60V
1.67V
1.70V
1.75V
1.80V
1.85V
Constant Current Discharge Characteristics Unit:A (25 ,77 )
5MIN 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR
24.1 19.2 15.6 9.05 4.88 2.67 1.93 1.53 1.29 0.901 0.739
23.1 18.3 14.9 8.81 4.73 2.60 1.90 1.51 1.28 0.886 0.729
22.6 17.8 14.5 8.68 4.65 2.57 1.87 1.50 1.27 0.879 0.725
21.8 17.0 13.9 8.46 4.53 2.51 1.83 1.46 1.24 0.864 0.709
20.8 16.2 13.2 8.19 4.39 2.46 1.78 1.42 1.21 0.849 0.693
19.6 15.3 12.5 7.87 4.28 2.40 1.75 1.38 1.17 0.826 0.677
Constant Power Discharge Characteristics Unit:W (25 ,77 )
5MIN 10MIN 15MIN 30MIN 1HR 2HR 3HR 4HR 5HR 8HR 10HR
258 210 173 103 54.0 29.8 22.0 18.0 15.3 10.5 8.78
251 202 166 101 53.3 29.1 21.8 17.8 15.0 10.4 8.64
247 199 162 99.3 52.9 28.8 21.6 17.6 14.9 10.2 8.57
240 192 156 97.4 52.3 28.2 21.2 17.3 14.5 10.1 8.45
231 185 151 95.0 51.5 27.7 20.8 16.8 14.1 10.0 8.29
222 177 146 92.2 50.6 27.2 20.4 16.4 13.8 9.73 8.14
20HR
0.375
0.369
0.367
0.360
0.352
0.345
20HR
4.46
4.40
4.36
4.28
4.20
4.12
RA: 0812