English
Language : 

GP12340_16 Datasheet, PDF (1/2 Pages) CSB Battery Co., Ltd. – Cells Per Unit 6 Voltage Per Unit 12
Powered by
GP 12340 12V 34Ah
Specification
GP 12340 is a general purpose battery up to 5 years in standby
service or more than 260 cycles at 100% discharge in cycle
service. As with all CSB batteries, all are rechargeable, highly
efficient, leak proof and maintenance free.
Cells Per Unit
Voltage Per Unit
Capacity
Weight
Maximum Discharge Current
Internal Resistance
Operating Temperature Range
Nominal Operating Temperature Range
Float Charging Voltage
Recommended Maximum Charging
Current Limit
Equalization and Cycle Service
Self Discharge
Terminal
Container Material
6
12
34 Ah @ 20hr-rate to 1.75V per cell @25°C (77°F)
Approx. 10.48 kg(23.06 lbs)
380A(5sec)
Approx. 8 mΩ
Discharge: -15°C~50°C ( 5°F~122°F)
Charge: -15°C~40°C ( 5°F~104°F)
Storage: -15°C~40°C ( 5°F~104°F)
25°C±3°C (77°F±5°F)
13.5 to 13.8 VDC/unit Average at 25°C (77°F)
10.2A
14.4 to 15.0 VDC/unit Average at 25°C (77°F)
CSB Batteries can be stored for more than 6 months at
25°C (77°F). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
B5-L terminal to accept M6 nut & bolt
ABS(UL 94-HB) & Flammability resistance of
(UL 94-V0) can be available upon request.
TUV Asia Pacific Ltd.
Taiwan Branch
TUV Asia Pacific Ltd.
Taiwan Branch
CSB-manufactured VRLA
(Absorbent Glass Mat type)
batteries are UL-recognized
components under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
Dimensions :
Unit: mm (inch)
Overall Height (H)
178.3±2 (7.02±0.08)
Container height (h)
154.8±2 (6.09±0.08)
Length (L)
195.6±2 (7.7±0.08)
Width (W)
130±1.5 (5.12±0.06)
(http://www.csb-battery.com)
The system of manufacturer was certified
by TUV CERT according to ISO 9001,ISO 14001.
F.V/Time
1.60V
1.67V
1.70V
1.75V
1.80V
1.85V
Constant Current Discharge Characteristics Unit:A (25°C,77°F)
5MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR
144 91.7 69.3 42.1 25.0 18.2 14.5 10.3 6.55 4.26 3.48
128 85.5 65.5 41.3 24.7 18.0 14.4 10.2 6.50 4.23 3.43
121 82.8 63.8 40.8 24.5 17.9 14.3 10.1 6.49 4.23 3.41
110 77.5 61.2 40.0 24.4 17.8 14.2 10.0 6.47 4.18 3.35
98.0 72.3 58.8 39.2 24.0 17.6 14.1 9.9 6.45 4.14 3.30
86.3 67.0 55.7 38.2 23.6 17.4 14.0 9.8 6.43 4.09 3.24
20HR
1.86
1.78
1.75
1.69
1.64
1.58
Constant Power Discharge Characteristics Unit:W (25°C,77°F)
F.V/Time 5MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR
1.60V 1732 1100 832 505 300 218 174 124 78.6 51.1 41.7
1.67V 1539 1026 788 495 297 216 173 123 78.1 50.8 41.1
1.70V 1456 994 771 490 295 215 172 122 77.9 50.7 40.9
1.75V 1316 931 739 481 292 213 171 121 77.7 50.2 40.3
1.80V 1176 867 705 470 288 212 170 120 77.4 49.6 39.6
1.85V 1036 804 669 458 283 209 169 119 77.2 49.1 39.0
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.
20HR
21.6
20.7
20.3
19.6
18.9
18.2
RA1406