GP 12260 12V 26Ah
Specification
GP 12260 is a general purpose battery up to 5 years in standby
service or more than 260 cycles at 100% discharge in cycle
service. As with all CSB batteries, all are rechargeable, highly
efficient, leak proof and maintenance free.
Cells Per Unit
Voltage Per Unit
Capacity
Weight
Maximum Discharge Current
Internal Resistance
Operating Temperature Range
Nominal Operating Temperature Range
Float Charging Voltage
Recommended Maximum Charging
Current Limit
Equalization and Cycle Service
Self Discharge
Terminal
Container Material
6
12
26 Ah @ 20hr-rate to 1.75V per cell @25°C (77°F)
Approx. 8.45 kg(18.63 lbs)
350A(5sec)
Approx. 11 mΩ
Discharge: -15°C~50°C ( 5°F~122°F)
Charge: -15°C~40°C ( 5°F~104°F)
Storage: -15°C~40°C ( 5°F~104°F)
25°C±3°C (77°F±5°F)
13.5 to 13.8 VDC/unit Average at 25°C (77°F)
7.8A
14.4 to 15.0 VDC/unit Average at 25°C (77°F)
CSB Batteries can be stored for more than 6 months at
25°C (77°F). Please charge batteries before using. For
higher temperatures the time interval will be shorter.
B1/B3/B3B-L terminal or Recessed type to accept M5 bolt
ABS(UL 94-HB) & Flammability resistance of
(UL 94-V0) can be available upon request.
TUV Asia Pacific Ltd.
Taiwan Branch
TUV Asia Pacific Ltd.
Taiwan Branch
CSB-manufactured VRLA
(Absorbent Glass Mat type)
batteries are UL-recognized
components under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
Dimensions :
Unit: mm (inch)
Overall Height (H)
125±1.5 (4.92±0.06)
Container height (h)
Length (L)
125±1.5 (4.92±0.06) 166±2 (6.54±0.08)
Width (W)
175±2 (6.89±0.08)
Drawing of recessed terminal
(http://www.csb-battery.com)
The system of manufacturer was certified
by TUV CERT according to ISO 9001,ISO 14001.
M5
F.V/Time
1.60V
1.67V
1.70V
1.75V
1.80V
1.85V
Constant Current Discharge Characteristics Unit:A (25°C,77°F)
5MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR
106 69.0 52.8 32.7 19.6 14.3 11.5 8.14 5.24 3.46 2.82
99.0 65.9 51.1 32.3 19.5 14.2 11.4 8.13 5.23 3.43 2.79
95.7 64.6 50.4 32.2 19.4 14.1 11.3 8.12 5.22 3.42 2.78
89.7 62.0 49.0 31.6 19.3 14.0 11.2 8.11 5.21 3.38 2.74
83.3 59.4 47.5 31.1 19.2 13.9 11.1 8.10 5.19 3.35 2.70
76.7 56.5 45.8 30.5 19.1 13.8 11.0 8.09 5.17 3.31 2.66
20HR
1.47
1.42
1.41
1.37
1.33
1.29
Constant Power Discharge Characteristics Unit:W (25°C,77°F)
F.V/Time 5MIN 10MIN 15MIN 30MIN 60MIN 90MIN 2HR 3HR 5HR 8HR 10HR
1.60V 1270 828 634 392 235 172 138 97.7 62.9 41.5 33.8
1.67V 1181 790 610 385 234 171 137 97.6 62.8 41.2 33.5
1.70V 1139 772 602 382 233 170 136 97.5 62.7 41.0 33.3
1.75V 1071 744 586 378 232 169 135 97.4 62.6 40.6 32.9
1.80V
999
713 570 373 231 168
134 97.3 62.3 40.2 32.4
1.85V
920
678 550 367 230 167
133 97.2 62.1 39.8 32.0
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.
20HR
17.6
17.1
16.9
16.5
16.0
15.6