English
Language : 

EVX12120_16 Datasheet, PDF (1/2 Pages) CSB Battery Co., Ltd. – It has high cycling life, high and long service life.l
Powered by
EVX 12120 12V 12Ah
Specification
EVX 12120 is designed specially for electric vehicles,
such as electric golf cart, electric wheelchair, mower,
dust collector...etc. It has high cycling life, high
efficiency and long service life.
Cells Per Unit
6
Voltage Per Unit
12
Capacity
Weight
Maximum Discharge Current
12Ah @ 20hr-rate to 1.75V per cell @25
Approx. 3.83 kg (8.44 lbs)
150A/180A(5sec)
(77 )
Internal Resistance
Operating Temperature Range
Approx. 18.5 m
Discharge: -15 ~50 ( 5 ~122 )
Charge: -15 ~40 ( 5 ~104 )
Storage: -15 ~40 ( 5 ~104 )
Nominal Operating Temperature Range
Float Charging Voltage
Recommended Maximum Charging
Current Limit
Equalization and Cycle Service
Self Discharge
25 3 (77 5 )
13.5 to 13.8 VDC/unit Average at 25 (77 )
3.6A
14.4 to 15.0 VDC/unit Average at 25 (77 )
CSB Batteries can be stored for more than 6 months at
25 (77 ). Please charge batteries before using. For
Terminal
Container Material
higher temperatures the time interval will be shorter.
F1/F2-Faston Tab187/250
ABS(UL 94-HB) & Flammability resistance of
(UL 94-V0) can be available upon request.
TUV Asia Pacific Ltd.
Taiwan Branch
TUV Asia Pacific Ltd.
Taiwan Branch
CSB-manufactured VRLA
(Absorbent Glass Mat type)
batteries are UL-recognized
components under UL1989.
CSB is also certified by
ISO 9001 and ISO 14001.
Dimensions :
Unit: mm (inch)
Overall Height (H)
100±1 (3.94±0.04)
Container height (h)
94±1(3.7±0.04)
Length (L)
151±2 (5.94±0.08)
Width (W)
98±1 (3.85±0.04)
(http://www.csb-battery.com)
The system of manufacturer was certified
by TUV CERT according to ISO 9001,ISO 14001.
Constant Current Discharge Characteristics Unit:A (25 ,77 )
F.V/Time
1.60V
1.67V
1.70V
1.75V
1.80V
1.85V
30MIN
12.8
12.7
12.6
12.4
12.0
11.3
60MIN
7.52
7.45
7.40
7.36
7.18
6.89
90MIN
5.46
5.45
5.41
5.36
5.28
5.08
2HR
4.32
4.29
4.28
4.25
4.17
3.99
3HR
3.14
3.10
3.09
3.07
3.00
2.90
4HR
2.45
2.44
2.43
2.41
2.38
2.30
5HR
2.06
2.05
2.04
2.01
1.99
1.92
8HR
1.36
1.35
1.34
1.33
1.32
1.27
10HR
1.13
1.12
1.11
1.09
1.07
1.04
20HR
0.655
0.633
0.615
0.600
0.585
0.570
Constant Power Discharge Characteristics Unit:W (25 ,77 )
F.V/Time
1.60V
1.67V
1.70V
1.75V
1.80V
1.85V
30MIN
146
146
144
143
140
132
60MIN
86.1
85.7
85.2
84.9
83.5
80.0
90MIN
63.4
62.9
62.7
62.3
61.2
59.4
2HR
50.5
50.1
50.0
49.5
49.0
47.4
3HR
36.8
36.6
36.4
36.2
35.7
34.5
4HR
29.3
29.1
28.9
28.8
28.5
27.7
5HR
24.4
24.3
24.2
23.9
23.7
23.0
8HR
16.2
16.1
16.0
15.9
15.7
15.2
10HR
13.4
13.3
13.2
13.1
12.9
12.5
Ratings presented herein are subject to revision without notice. Please refer to www.csb-battery.com to confirm the latest version.
20HR
7.13
7.09
7.06
7.01
6.87
6.66
RA1406