Step 1 1.1 Trim Cable as shown.
Step 2
2.1 Slide clamp nut over cable as shown.
2.2 Insert cable into solder ferrule until cable dielectric is flush with solder face of ferrule.
2.3 Solder both cable braids where shown.
2.4 Slide dielectric stop over cable center conductor and solder contact flush against stop to
dimension shown.
Step 3
3.1 Insert forward insulator into connector in orientation shown.
3.2 Insert cable/contact sub-assembly into connector until seated and tighten clamp nut to
35-45 in-lbs.