English
Language : 

CATTEN-01R5_08 Datasheet, PDF (2/2 Pages) CRYSTEK CORPORATION – 1.5dB Attenuator SMA 50 Ohm DC to 3GHz
Part Number Attenuation
CATTEN-01R0
CATTEN-01R5
CATTEN-02R0
CATTEN-03R0
CATTEN-04R0
CATTEN-05R0
CATTEN-06R0
CATTEN-07R0
CATTEN-08R0
CATTEN-09R0
CATTEN-0100
CATTEN-0150
CATTEN-0200
1 dB
1.5 dB
2 dB
3 dB
4 dB
5 dB
6 dB
7dB
8dB
9dB
10 dB
15 dB
20 dB
Power
(Max)
1 Watt
1 Watt
1 Watt
1 Watt
1 Watt
1 Watt
1 Watt
1 Watt
1 Watt
1 Watt
1 Watt
0.5 Watt
0.5 Watt
CATTEN-01R5
1.5dB Attenuator
SMA 50 Ohm
DC to 3GHz
1.5 dB Data
Freq. Atten
(MHz) (dB)
0.3 1.45
0.5 1.45
0.8 1.45
1.0 1.44
5.0 1.44
10.0 1.44
20.0 1.43
50.0 1.45
100.0 1.45
200.0 1.45
300.0 1.48
400.0 1.49
500.0 1.48
600.0 1.49
700.0 1.50
800.0 1.49
900.0 1.51
1000.0 1.49
1500.0 1.54
2000.0 1.62
2500.0 1.56
3000.0 1.78
Return Loss
Male Female
(dB) (dB)
74
66
74
66
74
66
74
66
70
66
69
65
63
63
57
56
51
50
46
44
43
42
41
40
39
39
38
37
36
36
35
35
34
34
33
33
28
29
23
24
20
20
18
17
TEST
Endurance Test at 70°C per EIA 575-3.14
Overload per EIA 575-3.6
Thermal Shock
Moisture Resistance
High Temperature Exposure
Low Temperature Exposure
Condition of Test
1000 hours at 70°C, 1.5 hrs “ON”, 0.5 hrs “OFF”
Short time overload
per EIA 575-3.5
per EIA 575-3.10
per EIA 575-3.7
per EIA 575-3.12
Test Results
0.5dB to 5dB 6dB to 20dB
± 0.2 dB
± 0.3 dB
± 0.2 dB
± 0.3 dB
± 0.2 dB
± 0.3 dB
± 0.2 dB
± 0.3 dB
± 0.2 dB
± 0.3 dB
± 0.2 dB
± 0.3 dB
Rev.: C