English
Language : 

HD4825-10 Datasheet, PDF (6/8 Pages) Crydom Inc., – Ratings from 12A to 125A 48-530 VAC
DataSPanhel eMoeuntt
AGENCY APPROVALS
Designed in accordance with the requirements of IEC 62314
IEC 61000-4-2 : Electrostatic Discharge – Level 3
IEC 61000-4-4 : Electrically Fast Transients – Level 3
IEC 61000-4-5 : Electrical Surges – Level 3
IEC 600068-2-6: Vibration 0.33mm and 0.75mm Amplitude over 10-55 Hz
IEC 600068-2-27: Shock Resistance 15g/11ms
E116949 (except 90, 110 and 125A models)
10143 UG
LR81689 (except 12, 110 and 125A models)
ACCESORIES
New Accessories!
Protective Cover & Hardware Kits
Protective Cover
Part number: KS101
Clear plastic cover
compatible with all new S1
designs. Safety covers
provide added protection
from electric shock when
installing or checking
equipment.
Hardware Kit
Part number: HK3
Bag with 2 threaded
standoffs, 2 screws 8-32 x
1/4, and 2 lockwashers
M8 for output, and 2
threaded standoffs, 2
screws 6-32 x 3/16, and 2
lockwashers M6 for input.
Standoff screws provide additional mounting options
such as "dead bug" mounting, using lug terminals or
wire terminals to the side of the relay.
Recommended Accessories
Cover
KS101
Hardware
Kit
Heat Sink
Part No.
Thermal Resistance Lug Terminal Thermal Pad
[ºC/W]
HK1 HS501DR
5.0
TRM1
HSP-1
HK3 HS301 / HS301DR
3.0
TRM6
HSP-2
HK4 HS251
2.5
HS201 / HS201DR
2.0
HS172
1.7
HS151 / HS151DR
1.5
HS103 / HS103DR
1.0
HS072
0.7
HS053
0.5
Hardware Kit
Part number: HK4
Bag with 2 square brass
accessories and 2 screw
8-32 x 5/8 for output. Used
to mount TMR1 lug
terminals.
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.