DataSPanhel eMoeuntt
AGENCY APPROVALS
EN60950 : Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7:
Designed in accordance with the requirements of IEC 62314
IEC61000-4-2 : Electrostatic Discharge – Level 3
IEC61000-4-4 : Electrically Fast Transients – Level 3
IEC61000-4-5 : Electrical Surges – Level 3
IEC 60068-2-6 : Vibration 0.35mm and 0.75mm Amplitude over 10-55 Hz
IEC 60068-2-27 : Shock Resistance 15g/11ms
E116949 (25, 50, 75 and 90A)
E116950 (25 and 125A)
LR81689
10143 UG
ACCESORIES
New Accessories!
Protective Cover & Hardware Kits
Protective Cover
Part number: KS101
Clear plastic cover
compatible with all new S1
designs. Safety covers
provide added protection
from electric shock when
installing or checking
equipment.
Hardware Kit
Part number: HK3
Bag with 2 threaded
standoffs, 2 screws 8-32 x
1/4, and 2 lockwashers
M8 for output, and 2
threaded standoffs, 2
screws 6-32 x 3/16, and 2
lockwashers M6 for input.
Standoff screws provide additional mounting options
such as "dead bug" mounting, using lug terminals or
wire terminals to the side of the relay.
Recommended Accessories
Cover
KS101
Hardware
Kit
Heat Sink
Part No.
Thermal Resistance Lug Terminal Thermal Pad
[ºC/W]
HK1 HS501DR
5.0
TRM1
HSP-1
HK3 HS301 / HS301DR
3.0
TRM6
HSP-2
HK4 HS251
2.5
HS201 / HS201DR
2.0
HS172
1.7
HS151 / HS151DR
1.5
HS103 / HS103DR
1.0
HS072
0.7
HS053
0.5
Hardware Kit
Part number: HK4
Bag with 2 square brass
accessories and 2 screw
8-32 x 5/8 for output. Used
to mount TMR1 lug
terminals.
Do not forget to visit us at: www.crydom.com
Copyright © 2013 Crydom Inc. Specifications subject to change without notice.