English
Language : 

M-OAC5AH Datasheet, PDF (3/5 Pages) Crydom Inc., – M SERIES OUTPUT MODULES
DatasI/OhMeodeultes
General Notes:
(1) Specifications apply to an ambient temperature of -30 to 80°C unless otherwise noted.
(2) Whitout external LED status indicator Add 1.7 volts for external LED if utilized.
(3) At nominal input voltage, without external LED status indicator.
(4) + / - 10% at 25°C.
(5) Maximum 1 minute duration for OAC modules when applied as a DC voltage rather than a peek AC voltage.
(6) At maximum line voltage, 25°C for OAC modules, and 80°C for ODC modules.
(7) Minimum DV/DT per EIA/NARM RS433, method RS397, DV/DT raitings do not apply to DC output models.
(8) At 40°C derate OAC modules 58 mA/°C to 80°C derate ODC, ODCxMC and ODCxML modules 50mA/°C
to 80°C CSA rating of OAC modules is 3.0 Arms at 40°C.
(9) At 25°C for 1 second maximum duration: 1 AC cycle for AC modules, 1 second for DC modules.
(10) At maximum rated on-state current and 25°C.
(11) At maximum line voltage, maximum rated output current, nominal input voltage and 25°C switching speed
of OAC modules is based upon 60 Hz line frequency
(12) At 25°C for 1 second maximum duration.
(13) 1/3 HP at 240 VAC 1/8 HP at 120 VAC.
(14) At 25°C for 1 second maximum duration.
EQUIVALENT CIRCUIT DIAGRAMS / MECHANICAL SPECIFICATIONS
CASE COLORS:
AC-BLACK
DC-RED
43
2
1
0.042 (1.1) DIA
1.7 (43.2)
0.3 (7.6)
0.7 (17.8)
1.2 (30.5)
1.4 (35.6)
UNLESS OTHERWISE SPECIFIED
DIMENSIONS: INCHES (MILLIMETERS)
TOLERANCE: ±0.020 (±0.50)
AGENCY APPROVALS
E46203
38595
Do not forget to visit us at: www.crydom.com
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.
Rev. 042017