H16WD6050-10 Datasheet, PDF (3/7 Pages) Crydom Inc., – H16WD Series
DatasPahneleMeoutnt
MECHANICAL SPECIFICATIONS (4)
Tolerances: ±0.02 in / 0.5 mm
All dimensions are in: inches [millimeters]
1.1
[27.9]
0.49
[12.4]
Screw Termination
Mounting
Hole/Slot
0.19 [4.9]
DIA.
1.88
[47.6]
1
OUTPUT
2
SOLID STATE RELAY
4
INPUT
3
1.7
[43.2]
Hex Standoff Termination (“K” Option) (2)
0.89
[22.6]
1.1
[27.9]
0.49
[12.4]
Mounting
Hole/Slot
0.19 [4.9]
DIA.
1.04
[26.4]
2.25
[57.3]
1.88
[47.6]
1
OUTPUT
2
SOLID STATE RELAY
4
INPUT
3
1.70
[43.2]
2.25
[57.3]
1.0
[25.4]
1.75
[44.5]
Quick Connect Termination (“F” Option) - Up to 25 Amp (1)
Mounting
Hole/Slot
0.19 [4.9]
DIA.
1.58
[40.2]
0.49
[12.4]
Faston Terminal(11)
0.25 x 0.032
(2 places)
1.31
[33.4]
1.88
[47.6]
1
OUTPUT
2
SOLID STATE RELAY
4
INPUT
3
1.7
[43.2]
2.25
[57.3]
1.0
[25.4]
1.75
[44.5]
0.93
[23.6]
(4 places)
1.0
[25.4]
(2 places)
Quick Connect Termination (“F” Option) - Up to 50 Amp (1)
Mounting
Hole/Slot
0.19 [4.9]
DIA.
1.58
[40.2]
0.63
[16.0]
Faston Terminal(11)
0.25 x 0.032
(4 places)
0.45
[11.4]
(2 places)
1.31
[33.4]
1.88
[47.6]
1
OUTPUT
2
SOLID STATE RELAY
4
INPUT
3
1.7
[43.2]
2.25
[57.3]
1.40
[35.6]
1.75
[44.5]
Faston Terminal(11)
0.187 x 0.020
(2 places)
1.25
[31.8]
0.49
[12.4]
1.40
[35.6]
1.75
[44.5]
Faston Terminal(11)
0.187 x 0.020
(2 places)
1.25
[31.8]
GENERAL NOTES
(1) Single pair (up to 25A) Double pair* (50A model only). *Caution: User must connect to both pairs.
(2) Option “K” is designed and tested for use with printed circuit boards or ring/fork terminals having a thickness between 0.031 and 0.093 inches (0.79 to 2.36 mm), and loads rated up to 50 Amps.
For higher load currents, the “K” standoff temperature must not exceed 105°C. For additional application assistance please contact Crydom Technical Support.
(3) Instantaneous turn-on version is not recomended for capacitive loads. Use zero turn-on only.
(4) All parameters at 25°C unless otherwise specified.
(5) Heat sinking required, see derating curves.
(6) Increase minimum voltage by 1V for operations from -20 to -30°C.
(7) Turn-on time for Instantaneous turn-on versions is 0.02 msec.
(8) All parameters at 50% power rating and 100% duty cycle (contact Crydom tech support for detailed report)
(9) Load can be wired to either SSR output terminal 1 or 2.
(10) Elective Input Status LED, “G” option.
(11) Mechanical dimensions vary from G3 models.
For additional information or specific questions, contact Crydom Technical Support.
Do not forget to visit us at: www.crydom.com
Copyright © 2016 Crydom Inc. Specifications subject to change without notice.