INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Maximum Turn-On Voltage
Minimum Turn-Off Voltage
Typical Input Current
Nominal Input Impedance
Maximum Turn-On Time [msec] (4)
Maximum Turn-Off Time [msec]
GENERAL SPECIFICATIONS
240 V Models
3-15 VDC
3.0 VDC
1.0 VDC
15 mA @5 VDC
300 Ohm
1/2 Cycle
1/2 Cycle
Description
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 V DC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range
Ambient Storage Temperature Range
Weight (typical)
Encapsulation
Power Terminals:
Control Terminals:
GENERAL NOTES
1) All parameters at 25°C unless otherwise specified.
2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1
3) Heat sink ing required, for derating curves see page 2.
4) Turn-on time for Random turn-on versions is 0.02 msec (DC Control Models)
480 V Models
4-15 VDC
4.0 VDC
1.0 VDC
15 mA @ 5 VDC
300 Ohm
1/2 Cycle
1/2 Cycle
90-140 Vrms
90 Vrms
10 Vrms
10 mA @ 120 VAC
14.1 K Ohm
10
40
Parameters
4000 Vrms
109 Ohm
10 pF
-30 to 80 °C
-40 to 125 °C
12 oz (340g)
Thermally conductive Epoxy
MS Screws Furnished, Mounted
.050 x .020 Square Pins