English
Language : 

CSD2410_11 Datasheet, PDF (1/5 Pages) Crydom Inc., – Panel Mount
CS Series
• Ratings from 10A to 90A @ 24-280 V AC
• 3-32 V DC input range
• Low off-state leakage current (snubberless)
• SCR output for heavy industrial loads
• Zero-crossing (resistive loads) or random-fire (inductive loads) output
PRODUCT SELECTION
Control Voltage
10A
3.5-15 VDC
CSD2410
15-32 VDC
CSE2410
AVAILABLE OPTIONS
25A
CSD2425
CSE2425
50A
CSD2450
CSE2450
75A
CSD2475
CSE2475
90A
CSD2490
CSE2490
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage (47-440Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2)
Maximum Load Current (3) [Arms]
Minimum Load Current [Arms]
Maximum 1 Cycle Surge Current (50/60) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum I² t for Fusing 50/60Hz (1/2 cycle) [A² sec]
Minimum Power Factor (with Maximum Load)
10A
24-280
600
1.0
500
10
0.15
115/120
1.6
1.48
66/60
0.5
25A
24-280
600
1.0
500
25
0.15
239/250
1.6
1.02
285/259
0.5
50A
24-280
600
1.0
500
50
0.15
597/625
1.6
0.63
1779/1621
0.5
75A
24-280
600
1.0
500
75
0.25
954/1000
1.6
0.31
4555/4150
0.5
90A
24-280
600
1.0
500
90
0.25
1145/1200
1.6
0.28
6560/5976
0.5