CL Series
• Ratings of 5A and10A @ 24-280 VAC
• UL Approved, CE and RoHS Compliant
• AC or DC control
• Zero-crossing (resistive loads) or random-fire (inductive loads) output
PRODUCT SELECTION
Control Voltage
3-32 VDC
90-250 VAC
AVAILABLE OPTIONS
5A
CL240D05
CL240A05
10A
CL240D10
CL240A10
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage (47-63Hz) [Vrms]
Transient Overvoltage [Vpk]
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (2)
Maximum Load Current [Arms] (3)
Minimum Load Current [mArms]
Maximum Surge Current (50/60Hz, 1 Cycle) [Apk]
Maximum On-State Voltage Drop @ Rated Current [Vpk]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum I² t for Fusing (50/60Hz, 1/2 cycle) [A² sec]
Minimum Power Factor (with Maximum Load)
5A
24-280
600
7
500
5
150
42/50
1.8
3.0
36/30
0.5
10A
24-280
600
7
500
10
150
84/100
1.5
2.5
48/40