English
Language : 

XQ-B Datasheet, PDF (2/11 Pages) Marktech Corporate – Cree XQ-B White Series on Board
XLamp® XQ-B LED
Characteristics
Characteristics
Thermal resistance, junction to solder point
Viewing angle (FWHM)
Temperature coefficient of voltage
ESD classification (HBM per Mil-Std-883D)
DC forward current
Reverse voltage
Forward voltage (@ 80 mA, 25 °C)
LED junction temperature
Unit
°C/W
degrees.
mV/°C
mA
V
V
°C
Minimum
Typical
17
140
-2.0
Class 1
80
3.0
Maximum
300
-5
3.4
150
Flux Characteristics (TJ = 25 °C)
The following table provides several base order codes for XLamp XQ-B LEDs. It is important to note that the base order codes listed here
are a subset of the total available order codes for the product family. For more order codes, as well as a complete description of the order-
code nomenclature, please consult the XLamp XQ LED Family Binning and Labeling document.
Color
Cool White
Neutral White
Warm White
CCT Range
Min.
5000 K
3700 K
2600 K
Max.
8300 K
5000 K
3700 K
Minimum Luminous Flux
@ 80 mA
Group
K2
K2
J3
J3
Flux (lm)
30.6
30.6
26.8
26.8
Calculated
Minimum
Luminous Flux
(lm)*
150 mA
52.5
52.5
46
46
Order Code
XQBAWT-00-0000-00000L051
XQBAWT-00-0000-00000H0E5
XQBAWT-00-0000-00000HXE5
XQBAWT-00-0000-00000HXE7
Notes:
• Cree maintains a tolerance of ±7% on flux and power measurements, ±0.005 on chromaticity (CCx, CCy) measurements and ±2 on CRI
measurements. See the Measurements section (page 7).
• Typical CRI for Neutral White, 3700 K - 5000 K CCT is 75.
• Typical CRI for Warm White, 2600 K - 3700 K CCT is 80.
• Minimum CRI for 70 CRI Minimum Cool White is 70.
• Minimum CRI for 80 CRI Minimum White is 80.
* Calculated flux values at 150 mA are for reference only.
Copyright © 2014-2016 Cree, Inc. All rights reserved. The information in this document is subject to change without notice. Cree® and XLamp® are registered trademarks and the Cree logo is a trademark of
Cree, Inc. UL® and the UR logo are registered trademarks of UL LLC.
2