English
Language : 

SMFL283R3S Datasheet, PDF (7/13 Pages) Interpoint Corporation Company – DC/DC CONVERTERS 28 VOLT INPUT
Crane Aerospace & Electronics Power Solutions
SMFL Single and Dual DC/DC Converters
28 Volt input – 65 Watt
Electrical Characteristics: -55°C to +125°C Tc, 28 VDC Vin, 100% load, RHA level O, unless otherwise specified.
DUAL output models
PARAMETER
CONDITIONS
OUTPUT VOLTAGE
OUTPUT CURRENT2
TC = 25°C
Vin = 16 to 40 VDC
+ VOUT
- VOUT
EACH OUTPUT
TOTAL OUTPUT
OUTPUT POWER
OUTPUT RIPPLE
± VOUT
LINE REGULATION
LOAD REGULATION
CROSS REGULATION
TC = 25°C
Vin = 16 to 40 VDC
10 kHz - 2 MHz
Vin = 16 to 40 VDC
NO LOAD TO FULL
+ VOUT
- VOUT
+ VOUT
- VOUT
SEE NOTE 3
SEE NOTE 4
INPUT VOLTAGE
CONTINUOUS
TRANSIENT1, 5 50 ms
SMFL2805D
SMFL2812D
SMFL2815D
MIN TYP MAX MIN TYP MAX MIN TYP MAX
4.95 5.00 5.05 11.88 12.00 12.12 14.85 15.00 15.15
4.92 5.00 5.08 11.82 12.00 12.18 14.77 15.00 15.23
0
—
70
—
3.5 0 — 3.03
0
—
10 0
—
5 0 — 4.33
0
—
50 0
—
60 0
—
65
— 50 100 — 50 120 — 50 150
—
0
50 —
0
50 —
0
50
— 25 100 — 25 100 — 25 100
—
0
50 — 10 50 — 10 50
— 25 100 — 50 120 — 150 150
—
5
8—
2
4—
2
4
—
3
6—
2
4—
2
4
16 28 40 16 28 40 16 28 40
—
—
50 —
—
50 —
—
50
INPUT CURRENT
INPUT RIPPLE CURRENT
EFFICIENCY
TC = 25°C
LOAD FAULT
TC = 25°C
STEP LOAD RESPONSE
± VOUT
STEP LINE RESPONSE1, 6
± VOUT
START-UP8
NO LOAD
INHIBITED–INH1
INHIBITED–INH2
10 kHz - 10 MHz
BALANCED LOAD
SHORT CIRCUIT
POWER DISSIPATION
RECOVERY1
50% - 100% - 50% TRANSIENT
RECOVERY1, 7
16 - 40 -16 VDC TRANSIENT7
RECOVERY
DELAY
— 50 120 — 50 100 — 50 100
—
9
14 —
9
14 —
9
14
— 35 70 — 35 70 — 35 70
— 30 50 — 30 50 — 30 80
75 78 — 81 84 — 82 85 —
— 12.5 16 — 10 14 — 10 14
— 1.5 4.0 — 1.5 4.0 — 1.5 4.0
— 250 350 — 450 600 — 500 600
— 1.5 3.0 — 1.5 3.0 — 1.5 3.0
— 250 300 — 250 400 — 250 400
— 200 300 — 200 300 — 200 300
—
3.5
6—
3.5
6—
3.5
6
UNITS
VDC
A
W
mV p-p
mV
mV
%
VDC
V
mA
mA p-p
%
W
ms
mV pk
ms
mV pk
µs
ms
Notes
1. Guaranteed by design, not tested.
2. Up to 70% of the total output power is available from either output providing the
opposite output is simultaneously carrying 30% of the total power.
3. Effect on negative Vout from 50%/50% loads to 70%/30% or
30%/70% loads.
4. Effect on negative Vout from 50%/50% loads to 50% then 10% load on negative
Vout.
5. Unit will shut down above approximately 45V but will be undamaged and will
restart when voltage drops into normal range.
6. Recovery time is measured from application of the transient to point at which Vout
is within 1% of final value.
7. Transition time > 10 µS.
8. Tested on release from inhibit.
9. Shall not compromise DC performance.
www.craneae.com
Page  of 13
Rev H - 20061102