Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
MCH SINGLE OUTPUT MODELS
MCH2805S
MCH2812S
MCH2815S
PARAMETER
OUTPUT VOLTAGE2
CONDITIONS
Tc = 25°C
MIN TYP MAX MIN TYP MAX MIN TYP MAX
4.95 5 5.05 11.88 12 12.12 14.85 15 15.15
Tc = â55°C TO +125°C 4.80 5 5.20 11.52 12 12.48 14.40 15 15.60
OUTPUT CURRENT
VIN = 12 to 50 VDC
â â 300 â â 125 â â 100
OUTPUT POWER
VIN = 12 TO 50 VDC
0 â 1.5 0 â 1.5 0 â 1.5
OUTPUT RIPPLE
10 kHz - 2 MHz
â 45 150 â 50 200 â 35 150
VOLTAGE
Tc = â55°C TO +125°C â 65 300 â 70 300 â 50 250
LINE REGULATION
VIN = 12 TO 50 VDC
â 35 120 â 60 250 â 70 350
Tc = â55°C TO +125°C â 40 120 â 70 250 â 80 350
LOAD REGULATION 10% TO FULL LOAD â 350 800 â 600 1400 â 700 1600
Tc = â55°C TO +125°C â 380 800 â 640 1400 â 760 1600
50% TO FULL1
â 100 200 â 145 300 â 165 350
Tc = â55°C TO +125°C â 115 300 â 160 400 â 185 450
INPUT VOLTAGE
NO LOAD TO FULL
CONTINUOUS
12 28 50 12 28 50 12 28 50
TRANSIENT1 120 ms 0 â 80 0 â 80 0 â 70
INPUT CURRENT
NO LOAD
â 5.5 11 â 6.0 12 â 6.0 12
Tc = â55°C TO +125°C â 6.0 11 â 6.5 12 â 6.5 12
INHIBITED
â 2.3 3.5 â 2.3 3.5 â 2.3 3.5
Tc = â55°C TO +125°C â 2.4 3.5 â 2.4 3.5 â 2.4 3.5
INPUT RIPPLE
CURRENT3
10k Hz - 10 MHz
â 100 200 â 100 200 â 100 200
Tc = â55°C TO +125°C â 130 250 â 150 250 â 150 250
EFFICIENCY
Tc = 25°C
72 77 â 74 79 â 74 79 â
LOAD FAULT4,5
Tc = â55°C TO +125°C 69 75 â 72 77 â 72 77 â
POWER DISSIPATION â 1.3 2.0 â 2.0 3.2 â 2.3 3.7
Tc = â55°C TO +125°C â 1.4 2.3 â 2.2 3.5 â 2.5 4.0
RECOVERY1
â 3.0 15 â 3.5 20 â 4.0 20
Tc = -â55°C TO +125°C â 3.5 15 â 3.5 20 â 4.0 20
STEP LOAD
RESPONSE6
50 %â100%â 50% LOAD
TRANSIENT
â500 185 500 â700 350 700 â700 350 700
Tc = â55°C TO +125°C â500 185 500 â800 380 800 â800 380 800
RECOVERY
â 125 500 â 130 500 â 140 600
Tc =â55°C TO +125°C â 125 600 â 130 600 â 180 750
STEP LINE
RESPONSE6
12 TTORA5N0STIOEN1T21VIN â500 170 500 â1000 400 1000 â850 400 850
Tc = â55°C TO +125°C â500 180 500 â1000 400 1000 â850 450 850
RECOVERY1
â 0.75 4.0 â 0.6 3.0 â 0.47 2.5
Tc = â55°C TO +125°C â 0.75 4.0 â 0.6 3.0 â 0.5 2.5
START-UP
DELAY
â 7 40 â 7 40 â 7 40
Tc = â55°C TO +125°C â 10 40 â 10 40 â 10 40
OVERSHOOT1
â 0 150 â 0 350 â 0 450
Tc = â55°C TO +125°C â 0 150 â 0 350 â 0 450
CAPACITIVE LOAD1
UNITS
VDC
mA
W
mV p-p
mV
mV
VDC
V
mA
mA p-p
%
W
ms
mV pk
μs
mV pk
ms
ms
mV pk
Notes:
1. Guaranteed by design, not tested.
2. Specified at 50% total Pout.
3. Lin = 2 μH.
4. Maximum duration of short circuit: 25°C-â 90 seconds, 125°C â 30 seconds.
5. Load fault is a short circuit (<50 mohms). Recovery is into resistive full load.
6. Transition ⥠10 μs. Recovery = time to settle to within 1% of Vout final value.
7. Max. spec indicates 80% of the converterâs total power, available from either
output.
www.craneae.com
Page 7 of 18