English
Language : 

SLH2805S Datasheet, PDF (5/10 Pages) Crane Aerospace & Electronics. – SLH Single and Dual DC/DC Converters
Crane Aerospace & Electronics Power Solutions
SLH Single and Dual DC/DC Converters
28 Volt input – 1.5 Watt – Pending Revision C Release
Electrical Characteristics: -55° to + 125°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
Single output models
PARAMETER
OUTPUT VOLTAGE 2
CONDITIONS
25°C
-55 to +125° C
OUTPUT CURRENT
Vin = 16 to 40 VDC
OUTPUT POWER
Vin = 16 to 40 VDC
OUTPUT RIPPLE
25°C, 10 kHz to 2 MHz
-55 to +125° C,
10 kHz to 2 MHz
LINE REGULATION
Vin = 16 to 40 VDC
LOAD REGULATION
LOAD 10% to 100%
INPUT VOLTAGE
NO LOAD TO FULL
CONTINUOUS
TRANSIENT 50 ms 1
INPUT CURRENT
NO LOAD
INHIBITED
INPUT RIPPLE
CURRENT 3
10 kHz - 10 MHz
EFFICIENCY
25°C, FULL LOAD
-55 to +125° C, FULL LOAD
LOAD FAULT 4, 5
SHORT CIRCUIT
POWER DISSIPATION
RECOVERY 1, 8
STEP LOAD
RESPONSE 1,5
50% - 100% - 50%
TRANSIENT
RECOVERY
STEP LINE
RESPONSE 6
16 - 40 -16 VDC
START-UP7
TRANSIENT
RECOVERY 1, 8
DELAY
OVERSHOOT 1
CAPACITIVE LOAD 1
25° C, NO EFFECT ON
DC PERFORMANCE
SLH2805S
MIN TYP MAX
4.95 5.00 5.05
4.80
—
5.20
—
—
300
—
—
1.5
—
65
150
—
—
250
—
115 300
—
440 700
16
28
40
—
—
50
—
2.9
17
—
1.3
5
—
85
250
72
79
—
69
—
—
—
0.4
1.5
—
—
30
— ±250 ±400
—
—
400
—
— ±600
—
—
500
—
1
20
—
—
500
—
—
100
SLH2812s
MIN TYP MAX
11.88 12.00 12.12
11.52 — 12.48
—
—
125
—
—
1.5
—
35
200
—
—
300
—
60
400
—
380 700
16
28
40
—
—
50
—
2.3
17
—
1.3
5
—
75
300
80
87
—
69
—
—
—
0.3
1.2
—
—
30
— ±220 ±700
—
—
400
—
-
±600
—
—
500
—
1
20
—
—
500
—
—
100
SLH2815s
MIN TYP MAX
14.85 15.00 15.15
14.40 — 15.60
—
—
100
—
—
1.5
—
60
200
—
—
300
UNITS
VDC
mA
W
mV p-p
—
60
650
mV
—
410 700
mV
16
28
40
VDC
—
—
50
V
—
2.4
17
—
1.3
5
mA
—
60
300 mA p-p
80
88
—
69
—
—
%
—
0.3
1.2
W
—
—
30
ms
—
±220 ±700 mV pk
—
—
400
µs
—
— ±600 mV pk
—
—
500
µs
—
1
20
ms
—
—
500 mV pk
—
—
100
µF
Notes:
All temperatures refer to case temperature, TC.
1. Guaranteed by design, not tested.
2. Specified at 50% load.
3. With a series inductor on the Vin power lead (Lin = 6 µH).
4. Maximum duration of short circuit: 90 seconds at 25°C, 30 seconds at 125°C.
5. Load fault is a short circuit into 1 . Recovery is into resistive full load.
6. Transition > 10 µs.
7. Measured from release of inhibit until Vout settles to within 1% of final value at full
load with Vin at 28V.
8. Recovery = time to settle to within 1% of Vout final value.
www.interpoint.com
Page 5 of 10
Rev C - 20090318 - Pending Revision C Release