28 Volt input â 1.5 Watt â Pending Revision C Release
Electrical Characteristics: -55° to + 125°C Tc, 28 VDC Vin, 100% load, unless otherwise specified.
Single output models
PARAMETER
OUTPUT VOLTAGE 2
CONDITIONS
25°C
-55 to +125° C
OUTPUT CURRENT
Vin = 16 to 40 VDC
OUTPUT POWER
Vin = 16 to 40 VDC
OUTPUT RIPPLE
25°C, 10 kHz to 2 MHz
-55 to +125° C,
10 kHz to 2 MHz
LINE REGULATION
Vin = 16 to 40 VDC
LOAD REGULATION
LOAD 10% to 100%
INPUT VOLTAGE
NO LOAD TO FULL
CONTINUOUS
TRANSIENT 50 ms 1
INPUT CURRENT
NO LOAD
INHIBITED
INPUT RIPPLE
CURRENT 3
10 kHz - 10 MHz
EFFICIENCY
25°C, FULL LOAD
-55 to +125° C, FULL LOAD
LOAD FAULT 4, 5
SHORT CIRCUIT
POWER DISSIPATION
RECOVERY 1, 8
STEP LOAD
RESPONSE 1,5
50% - 100% - 50%
TRANSIENT
RECOVERY
STEP LINE
RESPONSE 6
16 - 40 -16 VDC
START-UP7
TRANSIENT
RECOVERY 1, 8
DELAY
OVERSHOOT 1
CAPACITIVE LOAD 1
25° C, NO EFFECT ON
DC PERFORMANCE
SLH2805S
MIN TYP MAX
4.95 5.00 5.05
4.80
â
5.20
â
â
300
â
â
1.5
â
65
150
â
â
250
â
115 300
â
440 700
16
28
40
â
â
50
â
2.9
17
â
1.3
5
â
85
250
72
79
â
69
â
â
â
0.4
1.5
â
â
30
â ±250 ±400
â
â
400
â
â ±600
â
â
500
â
1
20
â
â
500
â
â
100
SLH2812s
MIN TYP MAX
11.88 12.00 12.12
11.52 â 12.48
â
â
125
â
â
1.5
â
35
200
â
â
300
â
60
400
â
380 700
16
28
40
â
â
50
â
2.3
17
â
1.3
5
â
75
300
80
87
â
69
â
â
â
0.3
1.2
â
â
30
â ±220 ±700
â
â
400
â
-
±600
â
â
500
â
1
20
â
â
500
â
â
100
SLH2815s
MIN TYP MAX
14.85 15.00 15.15
14.40 â 15.60
â
â
100
â
â
1.5
â
60
200
â
â
300
UNITS
VDC
mA
W
mV p-p
â
60
650
mV
â
410 700
mV
16
28
40
VDC
â
â
50
V
â
2.4
17
â
1.3
5
mA
â
60
300 mA p-p
80
88
â
69
â
â
%
â
0.3
1.2
W
â
â
30
ms
â
±220 ±700 mV pk
â
â
400
µs
â
â ±600 mV pk
â
â
500
µs
â
1
20
ms
â
â
500 mV pk
â
â
100
µF
Notes:
All temperatures refer to case temperature, TC.
1. Guaranteed by design, not tested.
2. Specified at 50% load.
3. With a series inductor on the Vin power lead (Lin = 6 µH).
4. Maximum duration of short circuit: 90 seconds at 25°C, 30 seconds at 125°C.
5. Load fault is a short circuit into 1 . Recovery is into resistive full load.
6. Transition > 10 µs.
7. Measured from release of inhibit until Vout settles to within 1% of final value at full
load with Vin at 28V.
8. Recovery = time to settle to within 1% of Vout final value.
www.interpoint.com
Page 5 of 10
Rev C - 20090318 - Pending Revision C Release
|
▷ |