English
Language : 

FMTR2812S Datasheet, PDF (3/8 Pages) Crane Aerospace & Electronics. – EMI FILTERED DC/DC CONVERTERS 28 VOLT INPUT
DC/DC CONVERTERS
FMTR SERIES
30 WATT
Electrical Characteristics: -55°C to +125°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.
DUAL OUTPUT MODELS
PARAMETER
OUTPUT VOLTAGE
CONDITIONS
25°C +VOUT
FMTR2805D
MIN TYP MAX
4.95 5.00 5.05
–VOUT 4.90 5.00 5.08
–55°C TO +125°C +VOUT 4.85 5.00 5.15
–VOUT 4.80 5.00 5.18
OUTPUT CURRENT1, 2 VIN = 17 TO 40 VDC
0
2.5 4.5
OUTPUT POWER1, 2
VIN = 17 TO 40 VDC
0
—
25
OUTPUT RIPPLE
25°C
—
75 140
10 kHz - 2 MHz
VOLTAGE +/– VOUT
—
— 180
LINE REGULATION
+VOUT
—
10
50
VIN = 17 TO 40VDC
–VOUT
—
50 100
LOAD REGULATION
+VOUT
—
NO LOAD TO FULL
–VOUT
—
CROSS REGULATION 25°C SEE NOTES 4 & 9
—
5
50
45 120
8
—
EFFECT ON –VOUT
INPUT VOLTAGE1
NO LOAD TO FULL
INPUT CURRENT
INPUT RIPPLE
CURRENT1
25°C SEE NOTES 5 & 9
CONTINUOUS
TRANSIENT 50 ms
NO LOAD
INHIBITED
10 kHz - 10 MHz
—
5
—
17
28
40
0
—
50
—
35
75
—
3
8
—
5
10
EFFICIENCY
25°C
75
77
—
LOAD FAULT6
STEP LOAD
RESPONSE ± VOUT
STEP LINE9
RESPONSE ± VOUT
START–UP1
72
POWER DISSIPATION
25°C
—
SHORT CIRCUIT
—
RECOVERY9
—
50 – 100 – 50% BALANCED
TRANSIENT
—
RECOVERY7, 9
—
17 – 40 – 17 VIN
TRANSIENT8
—
RECOVERY7
—
DELAY
—
OVERSHOOT9
74
—
—
10
—
12
1.4 5.0
±200 ±300
100 200
±200
—
1.4
±400
300
5
FULL LOAD
—
0
50
NO LOAD
—
50 250
FMTR2812D
FMTR2815D
MIN TYP MAX MIN TYP MAX
11.88 12.00 12.12 14.85 15.00 15.15
11.80 12.00 12.18 14.76 15.00 15.23
11.64 12.00 12.36 14.55 15.00 15.45
11.56 12.00 12.42 14.46 15.00 15.53
0
1.25 2.25
0
1.0
1.8
0
—
30
0
—
30
—
25
80
—
40
80
—
— 120 —
—
120
—
10
50
—
10
50
—
50 150 —
50
180
—
15
50
—
15
50
—
45 170 —
40
190
—
5
—
—
3
—
—
4
—
—
4
—
17
28
40 17 28
40
0
—
50
0
—
50
—
50
75
—
50
75
—
3
8
—
3
8
—
5
10
—
5
10
78
80
—
79
82
—
75
77
—
76
78
—
—
—
10
—
—
10
—
—
12
—
—
12
— 1.4 5.0 — 1.4 5.0
— ±150 ±300 — ±200 ±400
— 100 200 — 100 200
— ±200 ±400 — ±400 ±500
—
— 300 —
—
300
— 1.4
5
— 1.4
5
—
0
120 —
0
150
— 120 600 — 150 750
UNITS
VDC
A
W
mV p-p
mV
mV
%
VDC
V
mA
mA
mA p-p
%
W
ms
mV pk
µs
mV pk
µs
ms
mV pk
Notes
1. Tc = –55°C to +125°C.
2. Up to 90% of the total output current/power is available from either output
providing the positive output is carrying at least 10% of the total output
power.
3. Operation is limited below 17 V (see Figure 19).
4. Effect on the negative output under the following conditions:
+Pout 20% to 80%; –Pout 80% to 20%
5. Effect on the negative output under the following conditions:
+Pout 50%; –Pout 10% to 50%
6. Indefinite short circuit protection not guaranteed above 125°C case.
7. Recovery time is measured from application of the transient to point at which
Vout is within 1% of final value.
8. Transition time ≥ 10 µs.
9. Parameter shall be tested as part of device characterization and after design
and process changes. Thereafter, parameters shall be guaranteed to the
limits specified in the electrical Characteristics table.
3