VZX-6984A4 Datasheet, PDF (2/2 Pages) Communications & Power Industries, Inc. – 400W Compact Medium Power Amplifier
X-Band
OPTIONS:
• Remote Control Panel
• Redundant and Power
Combined Subsystems
• External Receive Band
Reject Filter
SPECIFICATIONS, VZX-6984A4
Electrical
Electrical (continued)
Frequency
Output Power
TWT
Flange
Bandwidth
Gain
RF Level Adjust Range
Gain Stability
Small Signal Gain Slope
Small Signal Gain Variation
Input VSWR
Output VSWR
Load VSWR
Residual AM
Phase Noise
IESS Phase Noise Profile
AC Fundamental
Sum of All Spurs
AM/PM Conversion
Harmonic Output
Noise and Spurious
(at rated gain)
Noise Figure
Intermodulation
Group Delay
(in any 40 MHz band)
7.9 to 8.4 GHz
400 W min. (56.02 dBm)
350 W min. (55.44 dBm)
500 MHz
75 dB min. at rated power output;
78 dB min. at small signal
0 to 20 dB
±0.25 dB/24hr max.
(at constant drive and temp.)
±0.02 dB/MHz max.
1.0 dB pk-pk max. across any 80 MHz band;
2.5 dB pk-pk max. across the 500 MHz band
1.3:1 max.
1.3:1 max.
2.0:1 max. operational; any value for operation
without damage
-50 dBc below 10 kHz
-20[1.3 +log F(kHz)] dBc, 10 kHz to 500 kHz
-85 dBc above 500 kHz
-6 dBc
-36 dBc
-47 dBc
3°/dB max. for a single carrier at
8 dB below rated power
-60 dBc at rated power, second and third
harmonics
<- 75 dBW/4 kHz from 7.25 to 7.75 GHz
<-65 dBW/4 kHz from 7.9 to 8.4 GHz
10 dB max.
-23 dBc or better typ. with two equal carriers
at total output power 7 dB below rated
single-carrier output
0.01 ns/MHz linear max.
0.001 ns/MHz2 parabolic max.
0.5 ns pk-pk ripple max.
Primary Power
110 - 240 VAC ±10%,
single phase, 47- 63 Hz
Power Consumption
1.3 kVA, typ.
1.5 kVA, max.
Power Factor
0.95 min.
Environmental (Operating)
Ambient Temperature
Relative Humidity
Altitude
Shock and Vibration
Acoustic Noise
Mechanical
Cooling (TWT)
RF Input Connection
RF Output Connection
RF Output Monitor
Dimensions (W x H x D)
Weight
-10° to +50°C operating
-40° to +70°C non-operating
95% non-condensing
10,000 ft. with standard adiabatic
derating of 2°C/1000 ft., operating;
40,000 ft., non-operating
Designed for normal transportation
environment per Section 514.4
MIL-STD-810E. Designed to
withstand 20G at 11 ms (1/2
sine pulse) in non-operating
configuration.
65 dBA @ 3 ft. from amplifier
Forced air with integral blower
Rear air intake & exhaust
Type N female
CPR-112G waveguide flange,
grooved with UNF 2B 8-32
threaded holes
Type N female
19 x 5.25 x 24 in.
(483 x 133 x 610 mm)
70 lbs (31.8 kg) max.
KEEPING YOU ON THE AIR
not up in the air
Certificate Number: 30515
For more detailed information, please refer to the corresponding CPI Technical Description.
Note: Specifications may change without notice as a result of additional data or product refinement.
Please contact CPI before using this information for system design.
MKT 152, ISSUE 3
07/06