TL22XI Datasheet, PDF (2/2 Pages) Communications & Power Industries, Inc. – 2.25 and 2.50 kW SuperLinear TWT Amplifiers
X-Band
OPTIONS &
C O M PA N I O N
PRODUCTS:
• Integral Linearizer
• Remote Control Panel
• Redundant and Power
Combined Subsystems
• External Receive Band
Reject Filter
• Integral L-Band Block
Upconverter (BUC)
SPECIFICATIONS, TL22XI and TL25XI
Electrical
Frequency
7.9 - 8.4 GHz
Output Power
TWT - TL22XI
TWT - TL25XI
Flange - TL22XI
Flange - TL25XI
2250 W min. (63.54 dBm)
2500 W min. (63.98 dBm)
1000 W max. operating (60.00 dBm)
1110 W max. operating (60.45 dBm)
Linear Power
TL22XI
TL25XI
1000 W with linearizer option
1110 W with linearizer option3
Bandwidth
500 MHz
Gain
75 dB min. at rated power output
78 dB min. at small signal
RF Level Adjust
0 to 30 dB continuous
Output Power Adjustability ±0.1 dB
Gain Stability
±0.25 dB/24 hr max.
(at constant drive and temp.)
Small Signal Gain Slope
0.02 dB/MHz max.
Small Signal Gain Variation
0.5 dB pk-pk max. over any 40 MHz;
3.0 dB pk-pk max. across the
500 MHz band;
4.0 dB pk-pk w/linearizer;
5.0 dB pk-pk w/ BUC;
6.0 dB pk-pk w/linearizer and BUC
Input/Output VSWR
1.25:1 max.
Load VSWR
2.0:1 max. for full spec compliance;
any value without damage
Residual AM, max.1
-50 dBc below 10 kHz,
-20 (1.5 +log F kHz) dBc,
10 kHz to 500 kHz (F in kHz)
-85 dBc above 500 kHz
Phase Noise1
IESS-308/309
phase noise continuous
AC fundamentals related
Sum of spurs
10 dB below mask at -10 dB backof
-50 dBc
-47 dBc
AM/PM Conversion
6°/dB max. With optional linearizer,
can be tuned to 2°/dB max.
Harmonic Output
-80 dBc
Noise and Spurious
-130 dBW/4 kHz from 3.4 to 4.2 GHz
-65 dBW/4 kHz from 4.2 to 12.0 GHz
-110 dBW/4 kHz from 12.0 to 40.0 GHz
Intermodulation
with two equal carriers,
total output power
level at 56 dBm
-23.5 dBc max, 7.9 - 8.4 GHz
(-25 dBc max. at 4 dB backoff
with linearizer);
Electrical (continued)
Group Delay
(in any 40 MHz band)
0.02 ns/MHz linear
0.002 ns/MHz2 parabolic
0.5 ns pk-pk ripple max.
Primary Power2
All ratings are ±10%, 47-63 Hz, 5-wire,
3-phase with neutral and ground
208 VAC (with or w/o neutral)
380 to 415 VAC
Power Factor
0.95 min.
Power Consumption
5.5 kW max.;
4.9 kW typ. @ 1000 W linear RF output
power;
4.2 kW typ. @ 800 W;
3.9 kW typ. @ 600 W;
3.6 kW typ. @ 400 W;
3.3 kW typ. @ 200 W;
2.8 kW typ. @ 100 W
(Power consumption 10% less for
2.25 kW HPA, typ.)
Environmental
Ambient Temperature
Relative Humidity
Altitude
Shock and Vibration
-10° to +50°C operating
-40° to +71°C non-operating
95% non-condensing
Up to 10,000 ft (3000 m) with standard
adiabatic derating of 2°/1000 ft.;
50,000 feet non-operating
Designed for normal transportation
environment per Section 514.4
MIL-STD-810E. Designed to withstand
20g at 11 ms (1/2 sine pulse) in
non-operating condition
Mechanical
Cooling(TWT)
RF Input Connection
RF Output Connection
RF Power Monitors
Dimensions (W x H x D)
Weight
Forced air with integral blower
and power supply fan. Maximum
external pressure loss allowable:
0.25 inch water gauge.
Type N female
CPR 112 F waveguide flange,
grooved, threaded UNF 2B 10-32
Type N female
19 x 15.75 x 24 in.
(483 x 400 x 610 mm)
155 lbs. (70.5 kg) max.
1Prime power AC line unbalance not to exceed 3%. Excess imbalance may cause
an increase in residual RF noise (AM, FM and PM). Phase noise increase is typically 2.5 dB / %
imbalance.
2AC current harmonic content: less than 20%, primarily fifth and seventh harmonics. Harmonics
must be considered when choosing UPS sources.
3Up to 1250 watts linear power available through optimization of linearizer settings.
Certificate Number: 30515
For more detailed information, please refer to the corresponding CPI Technical Description.
Note: Specifications may change without notice as a result of additional data or product refinement.
Please contact CPI before using this information for system design.
MKT 189, ISSUE 5