SPECIFICATIONS, T04XO Series
Electrical
Electrical (continued)
Frequency
Output Power
TWT
Flange
Bandwidth
7.9 - 8.4 GHz
400 W min. (56.02 dBm)
350 W min. (55.44 dBm)
500 MHz
Group Delay
(in any 40 MHz band)
Primary Power
0.01 ns/MHz linear max.
0.001 ns/MHz2 parabolic max.
0.5 ns pk-pk ripple max.
90-264 volts AC,
single phase 47-63 Hz
Gain
Gain Stability
At constant drive and temp.
Over temp. constant drive
Small Signal Gain Slope
Small Signal Gain Variation
RF Level Adjust Range
Attenuator Step-Size
Input VSWR
46 dB min. at rated power output
(70 dB with SSIPA)
52 dB min. at small signal
(75 dB with SSIPA)
±0.25 dB/24hr max. (after 30 min. warmup)
±1.0 dB over operating temp. range (any freq.);
±0.75 dB over ±10°C
±0.02 dB/MHz max. (±0.04 dB/MHz max.
with BUC option)
1.0 dB pk-pk across any 40 MHz band;
2.5 dB pk-pk across the 500 MHz band
4.0 dB pk-pk across 500 MHz with linearizer
4.5 dB pk-pk across 500 MHz with BUC
0 to 30 dB typ. (SSIPA option required)
0.1 dB (SSIPA option required)
1.3:1 max. (1.5:1 max. with BUC)
Power Consumption
1350 W typ.
1500 W max.
Power Factor
0.95 min.
Environmental (Operating)
Ambient Temperature
-40°C to +55°C operating,
including solar loading;
-40°C to +75°C non-operating
Relative Humidity
100% condensing
Altitude
10,000 ft. with standard adiabatic
derating of 2°C/1000 ft., operating;
50,000 ft., non-operating
Shock and Vibration
Designed for normal transportation
environment per Section 514.4
MIL-STD-810E. Designed to
withstand 20G at 11 ms (1/2
sine pulse) in non-operating
configuration.
Output VSWR
1.3:1 max.
Acoustic Noise
65 dBA @ 3 ft. from amplifier
Load VSWR
2.0:1 max. continuous operation;
any value for operation without damage
Heat Dissipation
Mechanical
1100 W max.
Residual AM
-50 dBc below 10 kHz
-20[1.5 +log F (kHz)] dBc,
10 kHz to 500 kHz
-85 dBc above 500 kHz
Phase Noise
IESS-308/309
12 dB below mask (3 dB below with BUC)
phase noise continuous
AC fundamentals related -50 dBc (-33 dBc with BUC)
Sum of spurs (370 Hz to 1 MHz) -47 dBc (-39 dBc with BUC)
AM/PM Conversion
2.5°/dB max. for a single carrier at
7 dB below rated power (2.5°/dB max. at
3 dB below rated with linearizer)
Cooling (TWT)
RF Input Connection
RF Output Connection
RF Output Monitor
Dimensions (W x H x D)
Weight
Forced air with integral blower
Type N female
CPR-112 G waveguide flange,
grooved with UNC 2B 10-32
threaded holes
Type N female
10.25 x 10.5 x 20.5 in.
(260 x 267 x 521 mm)
55 lbs (25.0 kg) with
no options, max.
Harmonic Output
-60 dBc at rated power
Noise and Spurious
(at rated gain)
<-70 dBW/4 kHz, passband
<-70 dBW/4 kHz, 7.25 to 7.75 GHz
Intermodulation
-24 dBc max. with two equal carriers
at total output power 7 dB (4 dB with
optional integral linearizer) below rated
single-carrier output
Certificate Number: 30515
For more detailed information, please refer to the corresponding CPI Technical Description.
Note: Specifications may change without notice as a result of additional data or product refinement.
Please contact CPI before using this information for system design.
MKT 129, ISSUE 7
06/08