English
Language : 

T04UO Datasheet, PDF (2/2 Pages) Communications & Power Industries, Inc. – 400W Outdoor TWT Amplifier
Ku-Band
OPTIONS:
• 1 RU Remote Control
Panel
• Extended Frequency
(12.75-14.5 GHz)
• Redundant and Power
Combined Subsystems
• Additional External
Receive Band Reject
Filter (increases loss
by a minimum 70 dB
up to 12.7 GHz)
• SSIPA with Variable
Attenuator (provides
RF Level Adjust Range of
0 to 30 dB)
• Integral Linearizer
(requires SSIPA with
attenuator option)
• Integrated 1:1 switch
control and drive
• L-Band Block
Upconverter (BUC ---
requires SSIPA option)
• Ethernet Interface
• Higher Operating
Temperature Limit
(+60°C)
• Circuit Breaker Package
(Note: this option is NOT
CE compliant)
SPECIFICATIONS, T04UO
Electrical
Electrical (continued)
Frequency
Output Power
TWT
Flange
Bandwidth
Gain
Gain Stability
At constant drive and temp.
Over temp. constant drive
Small Signal Gain Slope
Small Signal Gain Variation
RF Level Adjust Range
Attenuator Step Size
Input VSWR
Output VSWR
Load VSWR
Residual AM
Phase Noise
AC fundamental
Sum of all spurs
13.75 to 14.50 GHz
400 W min. (56.02 dBm)
350 W min. (55.44 dBm)
750 MHz (1750 MHz with ext. band option)
46 dB min. at rated power output
(70 dB with SSIPA);
52 dB min. at small signal
(75 dB with SSIPA)
±0.25 dB/24hr max. (after 30 min. warmup)
±1.0 dB over operating temp. range (any freq.);
±0.75 dB over ±10°C
±0.02 dB/MHz max. (±0.04 dB/MHz max.
with BUC option)
1.0 dB pk-pk across any 80 MHz band;
2.5 dB pk-pk across any 750 MHz band;
4.0 dB pk-pk across 1750 MHz band
(4.5 dB pk-pk across any 500 MHz, with
BUC option)
0 to 30 dB typ. (SSIPA option required)
0.1 dB (SSIPA option required)
1.3:1 max. (1.5:1 max. with BUC option)
1.3:1 max.
2.0 max. continuous operation; any value for
operation without damage
-50 dBc below 10 kHz
-20 [1.5 +log F(kHz)] dBc,
10 kHz to 500 kHz
-85 dBc above 500 kHz
12 dB below IESS-308 continuous mask
(3 dB below with BUC option)
-50 dBc (-33 dBc with BUC option)
-47 dBc (-39 dBc with BUC option)
Intermodulation
-24 dBc max. with two equal
carriers at total output power 7
dB (4 dB with optional integral
linearizer) below rated
single-carrier output
Group Delay
(in any 80 MHz band)
0.01 ns/MHz linear max.
0.001 ns/MHz2 parabolic max.
0.5 ns pk-pk ripple max.
Primary Power
90-264 VAC, single phase;
47-63 Hz
Power Consumption
1.35 kW, typ.
1.5 kW, max.
Power Factor
0.95 min.
Environmental (Operating)
Ambient Temperature
-40°C to +55°C operating,
including solar loading;
-40°C to +75°C non-operating
Relative Humidity
100% condensing
Altitude
10,000 ft. (3,048 m) with standard
adiabatic derating of 2°C/1000
ft. (305 m), operating; 50,000 ft.
(15,240 m), non-operating
Shock and Vibration
20 g pk, 11 msec, 1/2 sine
Acoustic Noise
65 dBA @ 3 ft. from amplifier
Mechanical
Cooling (TWT)
Forced air with integral blower
RF Input Connection
Type N female
RF Output Connection
WR-75 waveguide flange,
grooved with UNC 2B 6-32
threaded holes
RF Output Monitor
Type N female
Dimensions (W x H x D)
10.25 x 10.5 x 20.5 in.
(260 x 267 x 521 mm)
AM/PM Conversion
2.5°/dB max. for a single carrier up to
7 dB below rated power (2.5°/dB max. at
3 dB below rated with linearizer)
Weight
55 lbs (25.0 kg) max.,
with no options
Harmonic Output
-60 dBc at rated power
Noise and Spurious
(at rated gain)
<-150 dBW/4 kHz from 10.9 to 12.7 GHz
(to 11.7 GHz with ext. freq. option);
<-100 dBW/4 kHz, 11.7 to 12.2 GHz
(ext. freq. option only)
<-70 dBW/4 kHz transmit band to 18.0 GHz
<-65 dBW/4 kHz transmit band to 18.0 GHz,
(with optional linearizer)
<-105 dBW/4 kHz from 18.0 to 26.0 GHz
<-125 dBW/4 kHz from 26.0 to 40.0 GHz
Certificate Number: 30515
For more detailed information, please refer to the corresponding CPI Technical Description.
Note: Specifications may change without notice as a result of additional data or product refinement.
Please contact CPI before using this information for system design.
MKT 110, ISSUE 16
06/08
PDF