English
Language : 

T02UO-2G Datasheet, PDF (2/2 Pages) Communications & Power Industries, Inc. – 200W Outdoor TWT Amplifier
Ku-Band
OPTIONS:
• Remote Control Panel
• Redundant Subsystems
• Integrated 1:1 switch
control and drive
• Integral Linearizer
• Extended Frequency ---
12.75 - 14.50 GHz
• Integral L-Band Block
Upconverter (BUC
--- option is available
over 12.75 to 13.25 GHz
OR 13.75 to 14.50 GHz
frequency ranges only)
• Attenuated Solid State IPA
SPECIFICATIONS, T02UO-2G
Electrical
Electrical (continued)
Frequency
Output Power
TWT
Flange
13.75 to 14.50 GHz (output,
wideband option 12.75 to 14.50 GHz)
950 MHz to 1700 MHz (input w/BUC option)
Intermodulation
200 W min. (53.01 dBm)
175 W min. (52.43 dBm)
Primary Power
-24 dBc max. with respect to the
sum of both carriers at total output
power 7 dB OBO (4 dB OBO with
optional linearizer)
100-240 VAC ±10% single phase,
47-63 Hz
Bandwidth
750 MHz (1750 MHz with wideband option) Power Consumption
650 W typ.
Gain
Gain Stability
Small Signal Gain Slope
Small Signal Gain Variation
35 dB min. at rated power output
(68 dB min. with SSIPA option);
41 dB min. at small signal
(70 dB min. with SSIPA option)
±0.45 dB/24hr max.
(at constant drive and temp.)
±0.04 dB/MHz max.
1.0 dB pk-pk across any 80 MHz band;
3.5 dB pk-pk across the 750 MHz band
5.0 dB pk-pk across 1750 MHz
(wideband option)
Power Factor
0.95 min.
Environmental (Operating)
Ambient Temperature
-40°C to +60°C operating,
including solar loading;
-40°C to +71°C non-operating
Relative Humidity
100% condensing
Altitude
10,000 ft. with standard adiabatic
derating of 2°C/1000 ft., operating;
50,000 ft., non-operating
Shock
20 g pk, 11 mS, 1/2 sine
RF Level Adjust Range
30 dB typ. (not available with low gain version) Vibration
3 grms
Input VSWR
1.3:1 max.
Acoustic Noise
65 dBA @ 3 ft. from amplifier
Output VSWR
Load VSWR
MUXed External 10 MHz
Reference Phase Noise
Required (L-Band Input
950 - 1700 MHz) 1
BUC option only
Single Sideband Phase Noise
BUC option only
Residual AM
2.2:1 max. (1.3:1 max. with optional
output circulator)
2.0:1 max. continuous operation; any value for
operation without damage
-120 dBc/Hz at 10 Hz
-140 dBc/Hz at 100 Hz
-145 dBc/Hz at 1 kHz
-150 dBc/Hz at ≥10 kHz
(Level -3 to +7 dBm)
-63 dBc at 100 Hz offset
-73 dBc at 1 kHz offset
-83 dBc at 10 kHz offset
-93 dBc at 100 kHz offset
-103 dBc at 1 MHz offset
-113 dBc at ≥10 MHz offset
-50 dBc below 10 kHz
-20 [1.5 + log F(kHz)] dBc
10 kHz to 500 kHz
Mechanical
Cooling
L-Band Input Connection
RF Input Connection
RF Output Connection
RF Output Monitor
Dimensions (W x H x D)
Weight
Forced air with integral blower
Type N female (BUC option only)
Type N female (standard)
WR-75 waveguide flange,
grooved with UNC 2B 6-32
threaded holes
Type N female, 44 dB nom.
8.5 x 8.5 x 15.0 in. max.
(216 x 216 x 381 mm)
24.25 lbs (11.0 kg) with no options;
25.41 lbs (11.5 kg) with BUC
Note 1: External 10 MHz reference must be multiplexed with the RF input signal.
Phase Noise
12 dB below IESS-308 continuous mask
(3 dB below mask with BUC option)
Spurious
-60 dBc max. at 175 W flange output
AM/PM Conversion
2.0°/dB max. for a single carrier up to 7 dB
OBO (up to 4 dB OBO with linearizer option)
Harmonic Output
-60 dBc max. at rated power
Noise Power Density
(at maximum gain)
<-130 dBW/4 kHz, below 12.7 GHz
<-70 dBW/4 kHz, passband
<-66 dBW/4 kHz, passband with linearizer
Certificate Number: 30515
For more detailed information, please refer to the corresponding CPI Technical Description.
Note: Specifications may change without notice as a result of additional data or product refinement.
Please contact CPI before using this information for system design.
MKT 249, ISSUE 10
02/09
PDF