15 GHz
OPTIONS:
• Remote Control Panel
• Redundant Subsystems
• Integrated 1:1 switch
control and drive
• Integral Linearizer
SPECIFICATIONS, T02MO with BUC
Electrical
Electrical (continued)
Frequency
Output Power
TWT
Flange
1000 MHz to 1850 MHz (input)
14.50 to 15.35 GHz (output)
200 W min. (53.01 dBm)
175 W min. (52.43 dBm)
Intermodulation
Primary Power
-25 dBc max. with respect to the
sum of both carriers at total output
power of 40 W
100-240 VAC ±10% single phase,
47-63 Hz
Bandwidth
Gain
850 MHz
60 dB min. at rated power output;
64 dB typ. at small signal
Power Consumption
Power Factor
600 VA max.
500 VA typ. at 175 W output power
0.95 min.
Gain Stability
Small Signal Gain Slope
Small Signal Gain Variation
±0.25 dB/24hr max.
(at constant drive and temp.)
±0.04 dB/MHz max.
1.0 dB pk-pk across any 80 MHz band;
3.0 dB pk-pk across the 850 MHz band
Environmental (Operating)
Ambient Temperature
-40°C to +60°C operating,
including solar loading;
-40°C to +71°C non-operating
Relative Humidity
100% condensing
RF Level Adjust Range
Input VSWR
Output VSWR
Load VSWR
MUXed External 10 MHz
Reference Phase Noise
Required (L-Band Input
1000 - 1850 MHz)
30 dB typ.
Altitude
1.3:1 max.
2.2:1 max.
2.0:1 max. continuous operation; any value for
operation without damage
-115 dBc/Hz at 10 Hz
-140 dBc/Hz at 100 Hz
-145 dBc/Hz at 1 kHz
-150 dBc/Hz at ≥10 kHz
(Level -3 to +7 dBm)
Shock
Vibration
Acoustic Noise
Mechanical
Cooling
L-Band Input Connection
10,000 ft. with standard adiabatic
derating of 2°C/1000 ft., operating;
50,000 ft., non-operating
20 g pk, 11 mS, 1/2 sine
3 grms
65 dBA @ 3 ft. from amplifier
Forced air with integral blower
Type N female
Single Sideband Phase Noise
-63 dBc at 100 Hz offset
-73 dBc at 1 kHz offset
-83 dBc at 10 kHz offset
-93 dBc at 100 kHz offset
-103 dBc at 1 MHz offset
-113 dBc at ≥10 MHz offset
Spurious
-60 dBc max. at 175 W flange output
AM/PM Conversion
2.0°/dB max. for a single carrier up to 40 W
RF Output Connection
RF Output Monitor
Dimensions (W x H x D)
Weight
WR-62 waveguide flange,
grooved with UNC 2B 6-32
threaded holes
Type N female, 44 dB nom.
8.5 x 8.5 x 15 in. max.
(216 x 216 x 381 mm)
25 lbs (11.4 kg)
Harmonic Output
-60 dBc max. at 40 W output
Noise Power Density
(at maximum gain)
<-70 dBW/4 kHz, passband