SPECIFICATIONS
175 W Ka-band Outdoor LPA
Electrical
Model Number
Frequency
TWT
Flange
Bandwidth
Gain
at rated power
at small signal
RF Level Adjust Range
Attenuator Step Size
Small Signal Gain Slope
Small Signal Gain Variation
Gain Stability (at constant
drive and temperature)
VSWR
Input
Output
Load
Phase Noise
AM/PM Conversion
Noise and Spurious
(at rated gain)
Intermodulation
Group Delay
Linear
Parabolic
Ripple
Primary Power
Power Consumption
Power Factor
T01KO
User-specified frequency range within the 27.5 to 31.0 GHz band, as limited by bandwidth specification1
175 W (52.4 dBm)
145 W (51.6 dBm)
1000 to 2500 MHz, depending on desired frequency range1
70 dB min.
75 dB min. (70 dB min. with linearizer option)
0 to 25 dB
0.1 dB
±0.025 dB/MHz max.
1.0 dB pk-pk (across any 40 MHz segment within the passband); 2.5 dB pk-pk (across any 1000 MHz)
±0.25 dB/24 hours max. (after 30 minute warm-up)
±1.0 dB over temperature range -5˚C to +60˚C
1.3:1
1.3:1
1.5:1 max.; no degradation, infinite VSWR without damage
12 dB below IESS 308 continuous mask
2.5˚ /dB max. for a single carrier up to 6 dB OBO (1.0˚ /dB max. up to 3 dB OBO with linearizer)
<-150 dBW/4 kHz, below 21.2 GHz
<-70 dBW/4 kHz, 27.0 - 31.0 GHz (<-65 dBW/4 kHz with linearizer)
-24 dBc max @ 7 dB backoff from rated power (@ 4 dB backoff from rated power with linearizer)
(in any 40 MHz band)
0.01 nsec/MHz max.
0.001 nsec/MHz sq. max.
0.5 nsec pk-pk max.
100 - 240 VAC ± 10%, 47-63 Hz
750 VA typ, at saturated RF output power; 800 VA max.
0.95 min.
Environmental (operating)
Ambient Temperature
Relative Humidity
Altitude
Shock and Vibration
-40˚ to +60˚ C with extra margin for solar loading
100% condensing
10,000 ft with standard adiabatic derating of 2˚ C/1000 ft
20 g peak, 11 msec, 1/2 sin; 2.1 grms, 5 to 500 Hz
Mechanical
Cooling
RF Input Connection
RF Output Connection
RF Output Monitor
Dimensions (WxHxD)
Weight
Forced air with integral blower
WR-28F (WR-34F optional)
WR-34G (WR-28G optional)
2.9 mm SMA Female
10.25 x 9.5 x 20 inches (261 x 242 x 508 mm)
52 lbs (23.6 kg) max.
Heat and Acoustic
Heat Dissipation
Acoustic
600 W typ.
65 dBA typ.
Note 1: Please consult CPI representative to confirm that desired bandwidth is available over desired frequency range.
Mounting hardware is provided with each amplifier.