English
Language : 

VTX-6264D2X Datasheet, PDF (1/1 Pages) Communications & Power Industries, Inc. – VTX-6264D2X, 400 W, X-Band Helix TWT
VTX-6264D2X, 400 W, X-Band Helix TWT
400 Watt, 7.9 - 8.4 GHz, CW traveling
wave tube, periodic-permanent-magnet
focused, coaxial input, waveguide output,
conduction cooled.
Custom configurations are also available.
These variations in the performance and
configuration include: mechanical con-
figuration, electrical and RF connections,
and dual-stage depressed collector.
Features
• 400 Watt
• Coaxial Input
• Waveguide Output
• Weight:7.5 lbs. max
• Conduction Cooled
model
VTX-6264D2X
Frequency
(GHz)
7.9 - 8.4
Power output
(min)
400 W
TYPICAL OPERATING PARAMeters
MAXIMUM MINIMUM
Filament Voltage: 6.6
6.0
Filament Current: 5
---
Helix Voltage:
8.8
8.0
Helix Current: 15
---
Collector Voltage 1: .52 Ew
.48 Ew
Collector Current 1:
165
---
Cathode Current:
330
---
Collector Voltage 2:
.34 Ew
30 Ew
Collector Current 2:
330
---
Cathode Warm-up Time: ---
3
Drive Power:
10
---
Baseplate Temp:
110
---
Prime Power: ---
---
Load VSWR:
1.5:1
---
TYPICAL UNITS
--- Vdc
--- A
--- kVdc
--- mAdc
--- kVdc
--- mAdc
--- mAdc
--- kVdc
--- mAdc
--- Minutes
--- mW
--- °C
--- Watts
--- VSWR
The values listed above represent specified limits for the product and are subject to change. The data should be used for basic
information only. Formal, controlled specifications may be obtained from CPI for use in equipment design.
For information on this and other CPI products, visit our website at: www.cpii.com,
or contact: CPI MPP Division, 607 Hansen Way, Palo Alto, CA 94303
telephone: 1(800) 414-8823. fax: (650) 856-0705 | email: marketing@cpii.com
CPI10/09