English
Language : 

4CX15-000R Datasheet, PDF (1/1 Pages) Communications & Power Industries, Inc. – RF amplifier
4CX15,000R
The 4CX15,000R is identical to the 4CX15,000A
except that it has a mesh filament. The mesh fila-
ment is particularly well suited to FM service at
108 MHz due to reduced filament inductance. It
is also recommended for VHF TV linear amplifier
service to 225 MHz.
Characteristics
Plate Dissipation (Max.)
Screen Dissipation (Max.)
Grid Dissipation (Max.)
Frequency for Max. rating (CW)
Amplification Factor
Filament/Cathode
Voltage
Current
Capacitance
Input
Output
Feedthrough
Capacitance
Input
Output
Feedthrough
Cooling
Base
Air Socket
Air Chimney
Boiler
Length
Diameter
Weight
15,000 Watts
450 Watts
200 Watts
110 MHz
4.5
Thoriated Tungsten
6.3 Volts
160 Amps
Grounded Cathode
160.5 pf
24.5 pf
1.5 pf
Grounded Grid
67.0 pf
25.5 pf
0.2 pf
Forced Air
Special, Coaxial
SK-300A
SK-316
---
9.38 in; 238.00 mm
7.58 in; 193.00 mm
12.8 lb; 5.80 kg
Class of
Operation
C
C
AB1
AB1
---
Maximum Ratings
Typical Operation
Type of Service
RF amplifier
Plate modulated RF amplifier
RF linear amplifier
AF amplifier or modulator
Television linear amplifier
Plate
Voltage
(Volts)
Plate
Current
(Amps)
10,000
6.0
8,000
4.0
10,000
6.0
10,000
6.0
6,500
5.0
Plate
Voltage
(Volts)
Screen
Voltage
(Volts)
Plate
Current
(Amps)
Drive Output
Power Power
(Watts) (kiloWatts)
10,000
750
4.6
220
36.5
8,000
750
3.7
150
23.5
10,000 1,500
4.3
---
28.5
10,000 1,500
8.5
---
57.7
6,000
700
3.3
1,350 16.5
The values listed above represent specified limits for the product and are subject to change. The data should be used for basic
information only. Formal, controlled specifications may be obtained from CPI for use in equipment design.
For information on this and other CPI products, visit our website at: www.cpii.com,
or contact: CPI MPP Division, Eimac Operation, 607 Hansen Way, Palo Alto, CA 94303