English
Language : 

4CPL1000A Datasheet, PDF (1/1 Pages) Communications & Power Industries, Inc. – Pulse modulator or switch tube
4CPL1000A
This tube is designed for immersion in cooling a
liquid dielectric and can dissipate 1,000 watts.
In air with proper cooling, plate dissipation is
300watts. The 4CPL1000A mounting is optional.
This tube is rated to operate at an anode poten-
tial up to 15 kVdc when immersed in the recom-
mended coolant. When immersed, the rating is not
altitude dependant.
Characteristics
Plate Dissipation (Max.)
Screen Dissipation (Max.)
Grid Dissipation (Max.)
Frequency for Max. rating (CW)
Amplification Factor
Filament/Cathode
Voltage
Current
Capacitance
Input
Output
Feedthrough
Capacitance
Input
Output
Feedthrough
Cooling
Base
Air Socket
Air Chimney
Boiler
Length
Diameter
Weight
1,000 Watts
15 Watts
2 Watts
--- MHz
Oxide Coated
6.3 Volts
4.9 Amps
pf
pf
pf
pf
pf
pf
Liquid or Forced Air
Special with Solder
Terms
---
---
---
2.71 in; 68.83 mm
2.05 in; 51.94 mm
---
Class of
Operation
Maximum Ratings
Typical Operation
Type of Service
Pulse modulator or switch tube
Plate
Voltage
(Volts)
Plate
Current
(Amps)
15,000
8.0
Plate
Voltage
(Volts)
Screen
Voltage
(Volts)
Plate
Current
(Amps)
Drive Output
Power Power
(Watts) (kiloWatts)
7,000
700
The values listed above represent specified limits for the product and are subject to change. The data should be used for basic
information only. Formal, controlled specifications may be obtained from CPI for use in equipment design.
For information on this and other CPI products, visit our website at: www.cpii.com,
or contact: CPI MPP Division, Eimac Operations, 607 Hansen Way, Palo Alto, CA 94303
telephone: 1(800) 414-8823. fax: (650) 592-9988 | email: powergrid@cpii.com