English
Language : 

3CX5000H3 Datasheet, PDF (1/1 Pages) Communications & Power Industries, Inc. – Grid driven RF amplifier
3CX5000H3
The 3CX5000H3 is a forced air cooled, ceramic/
metal, medium-mu power triode designed primar-
ily for use in industrial radio frequency heating
services. Input of 23.6 kW is permissible up to 90
MHz. Plentiful reserve emission is available from
its 560 watt filament. The grid structure is rated
at 150 watts, making this tube an excellent choice
for industrial service.
Characteristics
Plate Dissipation (Max.)
Screen Dissipation (Max.)
Grid Dissipation (Max.)
Frequency for Max. rating (CW)
Amplification Factor
Filament/Cathode
Voltage
Current
Capacitance
Input
Output
Feedthrough
Capacitance
Input
Output
Feedthrough
Cooling
Base
Air Socket
Air Chimney
Boiler
Length
Diameter
Weight
5,000 Watts
---
150 Watts
90 MHz
18
Thoriated Tungsten
7.5 Volts
74.5 Amps
Grounded Cathode
51.0 pf
1.5 pf
25 pf
---
--- pf
--- pf
--- pf
Forced Air
Flexible Filament
Leads
---
SK-1316
---
17.50 in; 444.50 mm
6.45 in; 163.80 mm
10.0 lb ; 4.5 kg
Class of
Operation
C
C
C
AB
Maximum Ratings
Typical Operation
Type of Service
Grid driven RF amplifier
Grid driven RF amplifier plate modulated
RF Industrial oscillator
Grid driven AF amplifier or modulator
Plate
Voltage
(Volts)
Plate
Current
(Amps)
7,500
3.0
5,000
2.5
10,000
3.0
7,500
4.0
Plate
Voltage
(Volts)
Screen
Voltage
(Volts)
Plate
Current
(Amps)
Drive Output
Power Power
(Watts) (kiloWatts)
---
---
---
---
---
---
---
---
---
---
9,000
---
2.5
208
18.6
---
---
---
---
---
The values listed above represent specified limits for the product and are subject to change. The data should be used for basic
information only. Formal, controlled specifications may be obtained from CPI for use in equipment design.
For information on this and other CPI products, visit our website at: www.cpii.com,
or contact: CPI MPP Division, Eimac Operations, 607 Hansen Way, Palo Alto, CA 94303
telephone: 1(800) 414-8823. fax: (650) 592-9988 | email: powergrid@cpii.com