English
Language : 

RI-01B Datasheet, PDF (2/2 Pages) Coto Technology – Dry Reed Switch
RI-01B Series Dry Reed Switch
* The Contact Resistance is measured using the Kelvin Method next to the glass body.
sinewave; duration 11 ms). Such a shock will not cause
an open switch (no magnetic field present) to close,
nor a switch kept closed by an 80 AT coil to open.
Vibration
The switches are tested in accordance with “IEC
68-2-6”, test Fc (acceleration 10G; below cross-over
frequency 57 to 62 Hz; amplitude 0.75 mm;
frequency range 10 to 2000 Hz, duration 90 minutes).
Such a vibration will not cause an open switch (no
magnetic field present) to close, nor a switch kept
closed by an 80 AT coil to open.
Mechanical Strength
The robustness of the terminations is tested in accor-
dance with “IEC 68-2-21”, test Ua1 (load 40 N).
Operating and Storage Temperature
Operating ambient temperature; min: -55°C;
max: +125°C. Storage temperature; min: -55°C; max:
+125°C. Note: Temperature excursions up to 150°C
may be permissible. For more information contact your
nearest Coto Technology sales office.
Soldering
The switch can withstand soldering heat in accordance
with “IEC 68-2-20”, test Tb, method 1B: solder bath at
350 ±10°C for 3.5 ±0.5 s. Solderability is tested in
accordance with “IEC 68-2-20”, test Ta, method 3:
solder globule temperature 235°C; ageing 1b: 4 hours
steam.
Welding
The leads can be welded.
Mounting
The leads should not be bent closer than 1 mm to the
glass-to-metal seals. Stress on the seals should be
avoided. Care must be taken to prevent stray magnetic
fields from influencing the operating and measuring
conditions.
For Most Recent Data, Consult the Coto Technology Website: www.cotorelay.com 6 E-mail: sales@cotorelay.com