Test Parameters
Coil Resistance
Nominal Voltage
Must Operate Voltage
Must Release Voltage
Coil Resistance
Nominal Voltage
Must Operate Voltage
Must Release Voltage
Switching Voltage
Switching Current
Carry Current (Continuous)
Contact Rating (Resistive Load)
Life Expectancy Signal Switching3
Resistive Load3
Other Load Conditions3
Static Contact Resistance (initial)
Dynamic Contact Resistance (initial)
Insulation Res All Isolated Pins
Capacitance
Across Contacts
Capacitance
Open Contact to Coil
Capacitance
Closed Contact to Coil
Across Contacts
Dielectric
Contact to Coil
Strength
Contact to Shield
Operate Time (including bounce)
Release Time (Si diode damped)
RF Insertion Loss4
Signal Rise Time (10% - 90%)
Conditions1,2
3.3V Coil
5V Coil
Max DC/Peak AC
Switch and Shield
Resistive Load
1VDC / 10mA
12VDC / 10mA
Consult Factory
0.05VDC / 10mA
0.5V / 50mA 100 Hz, 1.5 mSec
100VDC
Shield Guarding
Shield Guarding
Shield Guarding
100 µA
100 µA
100 µA
Min
49.5
0.4
135.0
0.4
B10
Typ
55.0
5.0
150.0
5.0
1000
1
Max
60.5
4.0
2.4
165.0
6.0
3.8
125
0.25
0.5
3.0
Units
Ω
Volts DC
Volts DC
Volts DC
Ω
Volts DC
Volts DC
Volts DC
Volts
Amps
Amps
Watts
x 106 Ops
x 106 Ops
10!10
150
1500
1500
0.125
0.150
10 12
0.2
0.5
1
Ω
Ω
Ω
pF
pF
pF
V (DC/Pk AC)
V (DC/Pk AC)
V (DC/Pk AC)
Nominal Voltage coil drive @ 30 Hz,
100 200
square wave
30 50
-3 dB roll-off frequency
10.0
Corrected for measurement
40
system response time
µSec
µSec
GHz
pSec
NOTES:
1All parameters specified per EIA/NARM standards
for dry reed relays, # RS-421 and RS-436, if a
suitable parametric standard exists.
2Unless otherwise noted, all parameters are specified
at 25°C and 40% RH.
3Life expectancies based on characteristic life
(63.2% failure) calculated from the 2-parameter
Weibull distribution. Contact resistance >2.0Ω
defines end of life.
4Frequency at which the difference between output
and input signal amplitude exceeds -3dB. (Direct
wired using 50Ω coaxial cable.)
ENVIRONMENTAL RATINGS:
Storage Temperature: -35°C to +100°C.
Operating Temperature: -20°C to +85°C.
Vibration: sinusoidal vibration with an amplitude of
10G over a 10Hz to 2000Hz frequency range shall
not cause a closed channel activated at the nominal
coil voltage to open, not an open channel to close.
Max Soldering Temperature: 226°C (438°F) max for
1 minute dwell time. Temperature measured at a
relay ball termination.
For Most Recent Data, Consult the Coto Technology Website: www.cotorelay.com 6 E-mail: info@cotorelay.com