PZ-30_16 Datasheet, PDF (4/7 Pages) Copal Electronics – PRESSURE INDICATORS | |||
|
◁ |
PZ-30
PRESSURE INDICATORS
Ë ANALOG OUTPUT MODE
O Analog output setting : The second figure in triple digits LED indicates
output mode in the initial setting.
Output mode is fixed by rated pressure.
Analog output
âPr
Code
Output mode
â1â R mode (Compound)
1V
(4 mA)
â2â G mode (Positive)
â3â V mode (Negative)
5V
(20 mA)
0
(Vzero)
1V
(4 mA)
1V
(4 mA)
Pr
5V
(20 mA)
5V
(20 mA)
Ë SWITCH OUTPUT MODE
O Switch output can be set when blinking red LED indicates (SW2) in the intial setting.
O The mode is set at âSeparate (H/H), 1â prior to shipment. The mode is initialized at âSeparate (L/L), 4â when rated pressure is set at â-12Pâ or â-12Fâ (negative pressure).
0VUQVU
48
48
.PEF
4FQBSBUF
8JOEPXDPNQBSBUPS
4FQBSBUF
8JOEPXDPNQBSBUPS
0QFSBUJPO )* -0 "
#
)* -0 "
#
4
4
4
4
$
$
$
$
Pressure setting
(Operating point) 4FUUJOH
-PXFSMJNJU
4FUUJOH
6QQFSMJNJU
4FUUJOH
4FUUJOH
-PXFSMJNJU
4FUUJOH
6QQFSMJNJU
4FUUJOH
Note 1. In the Separate Mode, setting 1 corresponds to SW1, and Setting 2
corresponds to SW2.
Note 2. In the Window Comparator Mode, the minimum value for SW1 and SW2
corresponds to Setting 1 and the maximum value corresponds to Setting 2.
Separate mode
Window comparator mode
ʢHI operationʣ
ON
ON
ʢA operationʣ
ON
OFF
-Pr
P1: SW1
H
P2: SW2
P1
Pr -Pr
OFF
P2
Pr
H
H
H
Ê¢
LO operationʣ
ON
Ê¢
B operationʣ
ON
P1: SW1
-Pr
H
P2: SW2
H
OFF OFF
Pr
-Pr
P1
H
P2
H
OFF
Pr
P1ʽP2 or P1ʾP2
)ɿ Switch hysteresisɺ
1ʹ Setting 1 ɺ1ʹ Setting 2
P1ʽP2â2H
|
▷ |