English
Language : 

REC16D Datasheet, PDF (3/4 Pages) Copal Electronics – MANUAL SETTING TYPE OPTICAL ENCODERS
REC16D/REC16F
OPTICAL ENCODERS
˙ RELIABILITY TEST
The output shall satisfy the criteria below after the following tests.
Test item
Test conditions
Vibration
Power OFF
Amplitude : 1.52 mm or 98.1 m/s2 (10 G) whichever is smaller.
10 ~ 500 Hz excursion 15 min/cycle, 8 cycles each for X, Z, directions.
Shock
Power OFF
High temperature Power OFF
exposure
Power ON
Low temperature Power OFF
exposure
Power ON
Humidity
Power OFF
Thermal shock Power OFF
3 times each in directions (X, Z) at 490 m/s2 (50 G), 11 ms.
80 °C 96 h
50 °C 96 h
− 20 °C 96 h
(To be measured after leaving samples for 1 h at normal temperature and
humidity after the test.)
0 °C 96 h
°C Relative humidity ʙ ɹI
(To be measured after wiping out moisture and leaving samples for 1 h at normal temperature and humidity after the test.)
To be done 10 cycles with the following condition
(To be measured after leaving samples for 1 h at normal temperature and humidity after the test.)
°C Iɺ− °C I
˙ OUTLINE DIMENSIONS
O single shaft
15.7
5 – 2.54
M9P = 0.75
12345
6 Pin No
SOCKET (SAMTEC)
CES-106-01-S-S
Unless otherwise specified, tolerance: ± 0.4 (Unit: mm)
(11.55)
(8.13)
ʪAccessoriesʫ
3.86
0.5
16
O double shaft
15.7
5 – 2.54
M9P = 0.75
12345
6 Pin No
3.86
0.5
16
6.35
6.5
(17.4)
(8)
10 0.5
M 9 P = 0.75 11
2
1. Nut
SOCKET (SAMTEC)
CES-106-01-S-S
6.35
(11.55)
(8.13)
6.35
6.5
(8)
(9.5)
(17.4)
10 0.5
φ 9.4
0.5
φ 12.9
1
2. Washer
0.8 ± 0.05
φ 16
3.05 ± 0.08
3.16 ± 0.25
3. Locking Ring