PG-30 Datasheet, PDF (2/6 Pages) Copal Electronics – PRESSURE GAUGES | |||
|
◁ |
PG-30
PRESSURE GAUGES
Ë LIST OF MODEL NUMBERS
Pressure medium
Non-corrosive gases
Fitting
Rc 1/8
Switch output
interface
Pressure reference
Rated pressure range
NPN
PNP
ËVerify the above model numbers when placing orders.
â10 ~ 10 kPa
PG-30-101R-N
PG-30-101R-P
Gauge
â100 ~ 100 kPa â100 ~ 1000 kPa
PG-30-102R-N
PG-30-102R-P
PG-30-103R-N
PG-30-103R-P
Ë ACCESSORIES (Sold separately)
Name
Series name
Contents
Rear panel bracket set
ACPG-001
Rear panel bracket and M 3 Ã 4 male screw (2pcs.)
Applicable model
PG-30
Panel bracket set
Panel holder set
ACPG-002
ACPG-003
Panel bracket and M 3 Ã 4 male screw (2pcs.)
Panel holder cover
Panel holder
Panel stopper (2pcs.)
PG-30
PG-30 · PG-35 · PG-75 ·
PG-35H · PG-35L
Holder cover set
(For protecting gauge operating panel)
ACPG-004
Panel holder cover
Panel holder
PG-30 · PG-35 · PG-75 ·
PG-35H · PG-35L
Ë STANDARD SPECIFICATIONS
O Unless otherwise specified, the specs are defined at an ambient temperature of 25±5 °C and excitation voltage of 12 V DC.
Item
Model number
101R
PG-30
102R
Pressure reference
Gauge
Pressure medium
Non-corrosive gases
Rated pressure range
Maximum pressure
Break-down pressure
Operating temp. range
kPa
â10 ~ 10
kPa
20
kPa
50
°C
â100 ~ 100
200
500
â10 ~ 50
Compensated temp. range
Operating humidity
°C
%RH
0 ~ 50
35 ~ 85
Protection grade
In accordance with IEC IP65
Pressure port
2-Rc 1/8
Material of pressure port attachment
Aluminum die-casting, silicone
Net weight
g
Thermal error
Approx. ʢIncluding 2 m cableʣ
±3 %F.S. (0 ~ 50 °C)
Insulation resistance
Dielectric strength
Input voltage
Consumption current
100 MΩ minimumʢ%$7ʣ
1 minuteʢLeakage current 1 mA maximumʣ
10.8 ~ 30 V DCʢIncluding ripple percentageʣ
50 mA maximum
103R
â100 ~ 1000
1500
2000
|
▷ |