English
Language : 

PRCP-RX72 Datasheet, PDF (1/6 Pages) Copal Electronics – Polymer Resettable Circuit Protectors
*RoHS COMPLIANT
394
Features
72 V rated
Radial leaded devices
Cured,flame retardant epoxy polymer
insulating material meets
UL 94V-0 requirements
RoHS compliant* and halogen free**
Agency recognition:
Applications
Almost anywhere there is a low voltage
power supply, up to 72 V and a load to be
protected,including:
Security and fire alarm systems
Loudspeakers
Power transformers
PRCP-RX/72 Series - Polymer Resettable Circuit Protectors
Electrical Characteristics
Model
V max.
Volts
I max.
Amps
PRCP-RX020/72
72
40
PRCP-RX025/72
72
40
PRCP-RX030/72
72
40
PRCP-RX040/72
72
40
PRCP-RX050/72
72
40
PRCP-RX065/72
72
40
PRCP-RX075/72
72
40
PRCP-RX090/72
72
40
PRCP-RX110/72
72
40
PRCP-RX135/72
72
40
PRCP-RX160/72
72
40
PRCP-RX185/72
72
40
PRCP-RX250/72
72
40
PRCP-RX300/72
72
40
PRCP-RX375/72
72
40
Ihold
I trip
Amperes
at 23 °C
Hold
Trip
0.20
0.40
0.25
0.50
0.30
0.60
0.40
0.80
0.50
1.00
0.65
1.30
0.75
1.50
0.90
1.80
1.10
2.20
1.35
2.70
1.60
3.20
1.85
3.70
2.50
5.00
3.00
6.00
3.75
7.50
Initial
Resistance
Ohms
at 23 °C
Min.
Max.
1.50
2.84
1.00
1.95
0.76
1.36
0.52
0.86
0.41
0.77
0.27
0.48
0.18
0.40
0.14
0.31
0.15
0.25
0.12
0.19
0.09
0.14
0.08
0.12
0.05
0.08
0.04
0.06
0.03
0.05
1PHoosut-rT(Rrip1)
Resistance
Ohms
at 23 °C
Max.
4.40
3.00
2.10
1.29
1.17
0.72
0.60
0.47
0.38
0.30
0.22
0.19
0.13
0.10
0.08
Max. Time
To Trip
Amperes Seconds
at 23 °C at 23 °C
1.0
2.2
1.25
2.5
1.5
3.0
2.0
3.9
2.5
4.0
3.25
5.3
3.75
6.3
4.5
7.2
5.5
8.2
6.75
9.6
8.0
11.4
9.25
12.6
12.5
15.6
15.0
19.8
18.75
24.0
Tripped
Power
Dissipation
Watts
at 23 °C
Typ.
0.40
0.45
0.50
0.55
0.75
0.90
0.90
1.00
1.50
1.70
1.90
2.10
2.50
2.80
3.20
Environmental Characteristics
Operating/Storage Temperature ..........................-40 °C to 85 °C
Maximum Device Surface Temperature
in Tripped State..................................................125 °C
Passive Aging.......................................................+85 °C,1000 hours..........................................±5 % typical resistance change
Humidity Aging.....................................................+85 °C, 85 % R.H. 1000 hours........................±5 % typical resistance change
Thermal Shock.....................................................+85°C to -55 °C, 10 times...............................± 10% typical resistance change
Solvent Resistance. .............................................MIL-STD-202, Method 215..............................No change
Vibration...............................................................MIL-STD-883C, Method 2007.1,.....................No change
Condition A
Test Procedures And Requirements For Model PRCP-RX/72 Series
Test
Test Conditions
Accept/Reject Criteria
Visual/Mech..........................................................Verify dimensions and materials......................Per PRCP physical description
Resistance............................................................In still air @ 23°C.............................................Rmin ≤ R ≤ R1 max
Time to Trip..........................................................5 times Ihold,Vmax, 23 °C...............................T ≤ max. time to trip (seconds)
Hold Current.........................................................30 min at Ihold.................................................No trip
Trip Cycle Life......................................................Vmax, Imax, 100 cycles....................................No arcing or burning
Trip Endurance.....................................................Vmax, 48 hours................................................No arcing or burning
UL File Number....................................................E300792
CSA File Number..................................................CA1730526
TÜV Certificate Number.......................................R 50075506
* RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
** COPAL follows the prevailing definition of “halogen free” in the industry. COPAL considers a product to be “halogen free” if (a) the Bromine (Br) content is 900 ppm or less;
(b) the Chlorine (CI) content is 900 ppm or less; and (c) the total Bromine (Br) and Chlorine (CI) content is 1500 ppm or less.
Specifications are subject to change without notice.
The device characteristics and parameters in this data sheet can and do vary in different applications and actual device performance may vary over time.
Customers should verify actual device performance in their specific applications.