English
Language : 

PA-708_16 Datasheet, PDF (1/3 Pages) Copal Electronics – PRESSURE TRANSDUCERS WITH AMP
PA-708 PRESSURE TRANSDUCERS WITH AMP.
marking
Compatible with
EMC directive
INTERNAL STRUCTURE
2
1
34
˙ FEATURES
O Applicable for ultra high purity and aggressive fluids
O Compound pressure measures both positive and nega-
tive pressure
O PFA pressure port
Part name
1 Fluorocarbon polymer port
2 Fluorocarbon polymer diaphragm
3 Ceramic pressure sensor
4 Housing
Material
PFA
Alumina
PP
˙ MODEL NUMBER DESIGNATION
PA-708 - 102 R - 10 - P B
Series name
Rated pressure range
102ɿ−100 ~ 100 kPa
302ɿ−100 ~ 300 kPa
602ɿ−100 ~ 600 kPa
Pressure reference
RÉ¿Compound pressure
(Negative pressure ~ Positive pressure)
˙ LIST OF MODEL NUMBERS
Thermal error
Pressure reference
kPa
Rated pressure range
Fitting material
−100 ~ 100
± 0.1 % F.S./°C
−100 ~ 300
−100 ~ 600
˞ Verify the above model numbers when placing orders.
Gauge
PFA
PA-708-102R-10-PB
PA-708-302R-10-PB
PA-708-602R-10-PB
Fitting
BÉ¿PFA
Fitting material
PÉ¿Port type
Thermal error
10ɿ± 0.1 % F.S./°C