English
Language : 

MLVB04V18C0R5 Datasheet, PDF (2/2 Pages) Cooper Bussmann, Inc. – Multilayer Varistor ESD Suppressor
Environmental Specifications
Characteristic
Bias Humidity:
Thermal Shock:
Operating Temperature Range:
Storage Temperature Range:
Value
+40°C, 90% RH for 1000 hours
-40°C to +85°C, 30 minute cycle, 5 cycles
-40°C to +85°C
-40°C to +85°C
Soldering Recommendations
• Compatible with lead and lead-free solder reflow processes
• Peak reflow temperatures and durations:
- IR Reflow = 260°C max for 30 sec. max.
- Wave Solder = 260°C max. for 10 sec. max.
• Recommended IR Reflow Profile:
Dimensions - mm
W
C
L
H
Size
L
0402 1.00±0.15
0603 1.60±0.20
W
0.50±0.10
0.80±0.20
H
0.50±0.10
0.80±0.20
C
0.25±0.15
0.30±0.20
Tape Packaging Specifications - mm
Time (seconds)
Recommended Pad Layout - mm (in)
c
ba b
d
Size
a
b
c
d
0402 0.51 (0.020) 0.61 (0.024) 0.51 (0.020) 1.70 (0.067)
0603 0.50 (0.020) 1.02 (0.040) 0.76 (0.030) 2.54 (0.100)
AB
0.58 1.2
±0.03 ±0.03
0402 Carrier Dimensions
W E F P0 P1
8.0 1.75 3.5 4.0 2.0
±0.1 ±0.05 ±0.05 ±0.1 ±0.05
P2
2.0
±0.05
D0 T
1.55 0.60
±0.05 ±0.03
0603 Carrier Dimensions
0.90 1.80 8.0 1.75 3.50 4.00 -
2.00 1.50 -
±0.20 ±0.20 ±0.30 ±0.10 ±0.05 ±0.10 - ±0.05 ±0.10 -
The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is
intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change
design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information con-
tained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
Life Support Policy: Cooper Bussmann does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life sup-
port systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result
in significant injury to the user.
© 2010 Cooper Bussmann
St. Louis, MO 63178
www.cooperbussmann.com
0310 BU-SB10347
Page 2 of 2
Data Sheet 4071