Technical Data 4309
Effective July 2014
CC12H Series
High I2t Chip™ fuses
Electrical characteristics
Amp Rating
750mA-20A
1-3A
1-5A
1-5A
750mA, 6-20A
750mA-20A
% of Amp Rating
100%
200%
250%
300%
350%
1000%
Specifications
Opening Time
4 Hours, min
1-60 Seconds
5 Seconds, max
0.1-3 Seconds
5 Seconds, max
0.2-20mS
Environmental data
• Thermal Shock: MIL-STD-202, Method 107, Test Condition B
• Vibration: MIL-STD-202, Method 204, Test Condition C
• Moisture Resistance: MIL-STD-202, Method 106, 50 day cycle
• Solderability: ANSI/J-STD-002, Test B
• Normal ambient temperature: 23°C
• Operating temperature range -40°C to +125°C
Soldering method
• Wave Solder Immersion: 260°C, 10 seconds maximum.
• Solder Reflow: 260°C, 30 seconds maximum.
Catalog
Symbol
CC12H750mA
CC12H1A
CC12H1.5A
CC12H2A
CC12H2.5A
CC12H3A
CC12H3.5A
CC12H4A
CC12H4.5A
CC12H5A
CC12H6A
CC12H7A
CC12H8A
CC12H10A
CC12H12A
CC12H15A
CC12H20A
Current Rating
(amps)
0.75
1
1.5
2
2.5
3
3.5
4
4.5
5
6
7
8
10
12
15
20
Voltage Rating
(Vdc)
63
63
63
63
63
63
63
63
32
32
32
32
32
32
32
32
32
Interrupting
Rating* (amps)
50
50
50
50
50
50
50
50
100
100
100
100
100
100
100
100
100
Resistance
(Ω)** Typical
0.780
0.470
0.218
0.133
0.079
0.049
0.037
0.033
0.028
0.023
0.0155
0.011
0.007
0.0065
0.0045
0.0030
0.0020
Typical Melt
(I2t)† DC
0.15
0.18
0.4
1.1
1.7
2.2
2.7
3.2
4.2
6.0
8.0
9.0
12.0
33
45
40
50
Typical Voltage
Drop (mV)‡
840
490
355
305
240
185
180
169
160
140
140
120
80
90
80
70
60
Alpha
Marking
E
H
K
N
O
P
R
S
X
T
F
J
M
U
W
Y
Q
* DC Interrupting Rating (Measured at rated voltage, time constant of less than 50 microseconds, battery source)
** DC Cold Resistance (Measured at 10% of rated current)
† Typical Melting I2t (Measured with a battery bank at rated DC voltage, 10x-rated current, not to exceed interrupting rating, time constant of calibrated circuit less than 50
microseconds)
‡ Typical Voltage Drop (Measured at rated current after temperature stabilizes)
Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at
elevated ambient temperatures.
Dimensions - mm (in)
Pad layout
Drawing not to scale.
0.51 +/- 0.25 typ.
(0.02 +/- 0.01)
0.51 +/- 0.25 typ.
(0.02 +/- 0.01)
1.52 (0.06)
1.6 +/- 0.2 typ.
(0.063 +/- 0.008)
Top View
2.03 (0.08)
0.6 + 0.2, -0.15
(0.024 +0.008, -0.006)
Side View
3.2 +/- 0.2
(0.126 + /- 0.008)
2
www.eaton.com/elx
End View
1.6 +/- 0.2
(0.063 +/- 0.008)
1.52 (0.06)