English
Language : 

PTS181233V110 Datasheet, PDF (1/4 Pages) Cooper Bussmann, Inc. – 6-60 Volt DC Surface Mount, PolyTron PTC Devices
6-60 Volt DC Surface Mount, PolyTron™ PTC Devices
PolyTron™ PTS1812 Series
HALOGEN
Pb HF
FREE
Agency Information
• cURus: Recognized Card: File E343021 (Ihold 0.1-3.0A)
• TUV File: R 50192872
1812 Surface Mount Device
Description
• PolyTron™ surface mount PTC device
• 6 to 60 volts
• Current ratings from 0.1 to 3.0 amps
• Fast time-to-trip
• Low resistance
• Halogen free
• Lead free
• RoHS compliant
Part Number System/Ordering
PT S 1812 8V 110
PolyTron™ PTC Device Series
Surface Mount
Dimension Code
Maximum Voltage
Current Holding (Ihold)
Tape and Reel Packaging/Quantities
• PTS181216V035, PTS181216V050, PTS181213V075,
PTS18128V110, PTS18126V125, PTS18128V150,
PTS18128V160, PTS18128V200 - 2000 PTC devices per reel
• All Others - 1000 PTC devices per reel
Applications
• Medical equipment
• Telecommunications
• Rechargeable battery packs
• White goods
• Computers and peripherals
Catalog
Number
PTS181230V010
PTS181260V014
PTS181230V020
PTS181216V035
PTS181216V050
PTS181213V075
PTS181224V075
PTS181233V075
PTS18128V110
PTS181216V110
PTS181224V110
PTS18126V125
PTS181216V125
PTS18128V150
PTS181212V150
PTS181224V150
PTS18128V160
PTS18128V200
PTS18126V260
PTS18126V300
Mark
On
Part
T010
T014
T020
T035
T050
T075
T075 24
T075 33
T110
T110 16
T110 24
T125
T125 16
T150
T150 12
T150 24
T160
T200
T260
T300
Vmax
(Vdc)
30
60
30
16
16
13.2
24
33
8
16
24
6
16
8
12
24
8
8
6
6
Imax
(Amps)
100
10
100
100
100
100
100
20
100
100
20
100
100
100
100
20
100
100
100
100
Ihold
@23°C
(Amps)
0.10
0.14
0.20
0.35
0.50
0.75
0.75
0.75
1.10
1.10
1.10
1.25
1.25
1.50
1.50
1.50
1.60
2.00
2.60
3.00
Specifications
Itrip
@23°C
(Amps)
0.30
0.34
0.40
0.70
1.00
1.50
1.50
1.50
2.20
2.20
2.20
2.50
2.50
3.00
3.00
3.00
3.20
3.50
5.00
5.00
Pd
Resistance (W)
Typ. Time to Trip (Max.) Initial (Ri) Post Trip (R1)
(W) (Amps) (Sec) Min.
Max.
0.8
0.5
1.5
1.6
15
0.8
1.5 0.15
1.5
6
0.8
8
0.02
0.8
5
0.8
8
0.1
0.32
1.5
0.8
8
0.15 0.15
1
0.8
8
0.2
0.11
0.45
0.8
8
0.2
0.11
0.4
0.8
8
0.2
0.11
0.4
0.8
8
0.3
0.04
0.21
0.8
8
0.5
0.06
0.18
0.8
8
0.5
0.06
0.2
0.8
8
0.4
0.05
0.14
0.8
8
0.4
0.05
0.14
0.9
8
0.3
0.04
0.11
0.9
8
0.5
0.04
0.11
0.9
8
1.5
0.04
0.12
0.8
8
1.0
0.03
0.1
1.2
8
2.0
0.02
0.06
1.2
8
2.5 0.015
0.047
1.2
8
4.0 0.012
0.04
Agency
Information
cURus TUV
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
XX
Notes:
Ihold – Hold current: Maximum current device will pass without interruption in 23°C still air.
Itrip – Trip current: Minimum current that will switch the device from low resistance to high resistance in 23°C still air.
Vmax: Maximum continuous voltage device can withstand without damage at rated current.
Imax: Maximum fault current device can withstand without damage at rated voltage.
Pd: Power dissipated from device when in the tripped state in 23°C still air.
Ri (min.): Minimum resistance of device as supplied at 23°C unless otherwise specified.
R1(max.): Maximum resistance of device when measured one hour post reflow (SMD) or one hour post trip (radial-leaded device) at 23°C unless otherwise specified.
0413 BU-SB13507
Page 1 of 4
Data Sheet 4398