English
Language : 

PTR060V0010 Datasheet, PDF (1/4 Pages) Cooper Bussmann, Inc. – 60 Volt DC Radial Leaded, PolyTron™ PTC Devices
60 Volt DC Radial Leaded, PolyTron™ PTC Devices
PolyTron™ PTR060V Series
HALOGEN
Pb HF
FREE
Radial Leaded Device
Description
• PolyTron™ radial leaded thru-hole PTC device
• Maximum 60 volts
• Current ratings from 0.10 to 3.75 amps
• Fast time-to-trip
• Low resistance
• Halogen free
• Lead free
• RoHS compliant
Agency Information
• cURus: Recognized Card: File E343021 (Ihold 0.1-3.75A)
• TUV File: J 50194729
Part Number System/Ordering
PT R 060V 0160 -TR
PolyTron™ PTC Device Series
Radial Leaded
Maximum Voltage
Current Holding (Ihold)
Tape and Reel Packaging and Lead Type Code
Lead Codes: TR & BK - Straight Leads, TR1 & BK1 - Kinked Leads
TR & TR1 On Reels
• 0.10, 0.20-0.40A - 3000 devices
• 0.17 - 2,500A devices
• 0.50-0090A - 2000 devices
• 1.10-1.85A - 1500 devices
• 2.50-3.75A - 1000 devices
BK & BK1 In Poly Bags
• 0.10-0.25A - 1000 devices
• 0.30-1.85A - 500 devices
• 2.50-3.75A - 250 devices
Applications
• Medical equipment
• White goods
• Industrial power transmission • Telecommunications
• Computers and peripherals • Consumer and automotive electronics
• Rechargeable battery packs
Catalog
Number
PTR060V0010
PTR060V0017
PTR060V0020
PTR060V0025
PTR060V0030
PTR060V0040
PTR060V0050
PTR060V0065
PTR060V0075
PTR060V0090
PTR060V0110
PTR060V0135
PTR060V0160
PTR060V0185
PTR060V0250
PTR060V0300
PTR060V0375
Vmax
(Vdc)
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
60
Imax
(Amps)
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
Ihold
@23°C
(Amps)
0.10
0.17
0.20
0.25
0.30
0.40
0.50
0.65
0.75
0.90
1.10
1.35
1.60
1.85
2.50
3.00
3.75
Itrip
@23°C
(Amps)
0.20
0.34
0.40
0.50
0.60
0.80
1.00
1.30
1.50
1.80
2.20
2.70
3.20
3.70
5.00
6.00
7.50
Specifications
Pd
Time to
Typ.
Trip (Max.)
(W) (Amps) (Sec)
0.38 0.50
4.0
0.48 0.85
3.0
0.41 1.00
2.2
0.45 1.25
2.5
0.49 1.50
3.0
0.56 2.00
3.8
0.77 2.50
4.0
0.88 3.25
5.3
0.92 3.75
6.3
0.99 4.50
7.2
1.50 5.50
8.2
1.70 6.75
9.6
1.90 8.00 11.4
2.10 9.25 12.6
2.50 12.50 15.6
2.80 15.00 19.8
3.20 18.75 24.0
Resistance (Ω)
Initial (Ri)
Post Trip (R1)
Min. Max.
Max.
2.500 4.500
7.50
3.300 5.210
8.00
1.830 2.750
4.40
1.250 1.950
3.00
0.880 1.330
2.10
0.550 0.860
1.29
0.500 0.770
1.17
0.310 0.480
0.72
0.250 0.400
0.60
0.200 0.310
0.47
0.150 0.250
0.38
0.120 0.190
0.30
0.090 0.140
0.22
0.080 0.120
0.19
0.050 0.080
0.13
0.040 0.060
0.10
0.030 0.050
0.08
Agency
Information
cURus TUV
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Notes:
Ihold – Hold current: Maximum current device will pass without interruption in 23°C still air.
Itrip – Trip current: Minimum current that will switch the device from low resistance to high resistance in 23°C still air.
Vmax: Maximum continuous voltage device can withstand without damage at rated current.
Imax: Maximum fault current device can withstand without damage at rated voltage.
Pd: Power dissipated from device when in the tripped state in 23°C still air.
Ri (min.): Minimum resistance of device as supplied at 23°C unless otherwise specified.
Ri (max.): Maximum resistance of device as supplied at 23°C unless otherwise specified.
R1(max.): Maximum resistance of device when measured one hour post reflow (SMD) or one hour post trip (radial-leaded device) at 23°C unless otherwise specified.
0111 BU-SB11020
Page 1 of 4
Data Sheet 4401