English
Language : 

PTR030V0090 Datasheet, PDF (1/4 Pages) Cooper Bussmann, Inc. – 30 Volt DC Radial Leaded, PolyTron™ PTC Devices
30 Volt DC Radial Leaded, PolyTron™ PTC Devices
PolyTron™ PTR030V Series
HALOGEN
Pb HF
FREE
Radial Leaded Device
Description
• PolyTron™ radial leaded thru-hole PTC device
• Maximum 30 volts
• Current ratings from 0.90 to 9.00 amps
• Fast time-to-trip
• Low resistance
• Halogen free
• Lead free
• RoHS compliant
Agency Information
• cURus: Recognized Card: File E343021 (Ihold 0.9-9A)
• TUV File: J 50194729
Part Number System/Ordering
PT R 030V 0160 -TR
PolyTron™ PTC Device Series
Radial Leaded
Maximum Voltage
Current Holding (Ihold)
Tape and Reel Packaging and Lead Type Code
Lead Codes: TR & BK - Straight Leads, TR1 & BK1 - Kinked Leads
TR & TR1 On Reels
• 0.90-1.60A - 3000 devices
• 1.85-3.00A - 2000 devices
• 4.00-9.00A - 1000 devices
BK & BK1 In Poly Bags
• 0.90-1.35A - 1,000 devices
• 1.60-6.00A - 500 devices
• 7.00-9.00A - 250 devices
Applications
• Medical equipment
• White goods
• Industrial power transmission
• Telecommunications
• Computers and peripherals
• Consumer and automotive electronics
• Rechargeable battery packs
Catalog
Number
PTR030V0090
PTR030V0110
PTR030V0135
PTR030V0160
PTR030V0185
PTR030V0250
PTR030V0300
PTR030V0400
PTR030V0500
PTR030V0600
PTR030V0700
PTR030V0800
PTR030V0900
Vmax
(Vdc)
30
30
30
30
30
30
30
30
30
30
30
30
30
Imax
(Amps)
40
40
40
40
40
40
40
40
40
100
100
100
100
Ihold
@23°C
(Amps)
0.90
1.10
1.35
1.60
1.85
2.50
3.00
4.00
5.00
6.00
7.00
8.00
9.00
Itrip
@23°C
(Amps)
1.80
2.20
2.70
3.20
3.70
5.00
6.00
8.00
10.00
12.00
14.00
16.00
18.00
Specifications
Pd
Time to
Typ.
Trip (Max.)
(W) (Amps) (Sec)
0.6 4.50 5.90
0.7 5.50 6.60
0.8 6.75 7.30
0.9 8.00 8.00
1.0 9.25 8.70
1.2 12.50 10.30
2.0 15.00 10.80
2.5 20.00 12.70
3.0 25.00 14.50
3.5 30.00 16.00
3.8 35.00 17.50
4.0 40.00 18.80
4.2 45.00 20.00
Resistance (Ω)
Initial (Ri)
Post Trip (R1)
Min. Max.
Max.
0.070 0.120
0.22
0.050 0.100
0.17
0.040 0.080
0.13
0.030 0.070
0.11
0.030 0.060
0.09
0.020 0.040
0.07
0.020 0.050
0.08
0.010 0.030
0.05
0.010 0.030
0.05
0.005 0.020
0.04
0.005 0.020
0.03
0.005 0.013
0.02
0.005 0.010
0.02
Agency
Information
cURus TUV
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Notes:
Ihold – Hold current: Maximum current device will pass without interruption in 23°C still air.
Itrip – Trip current: Minimum current that will switch the device from low resistance to high resistance in 23°C still air.
Vmax: Maximum continuous voltage device can withstand without damage at rated current.
Imax: Maximum fault current device can withstand without damage at rated voltage.
Pd: Power dissipated from device when in the tripped state in 23°C still air.
Ri (min.): Minimum resistance of device as supplied at 23°C unless otherwise specified.
Ri (max.): Maximum resistance of device as supplied at 23°C unless otherwise specified.
R1 (max.): Maximum resistance of device when measured one hour post reflow (SMD) or one hour post trip (radial-leaded device) at 23°C unless otherwise specified.
0111 BU-SB11019
Page 1 of 4
Data Sheet 4400