English
Language : 

PCH-1-1 Datasheet, PDF (1/2 Pages) Cooper Bussmann, Inc. – Subminiature, Radial Leaded, Fast-Acting Fuses PC-Tron Series
Subminiature, Radial Leaded, Fast-Acting Fuses
PC-Tron Series
Radial Leaded Device
Description
• Radial leaded, fast-acting thru-hole fuse
• Ideal for high voltage DC applications
• Board washable
• Optional mounting socket available (PCS)
• Available in different lead configurations
AC Time-Current Characteristics
% of Amp Rating
Opening Time
100%
4 hours minimum
200%
10 second maximum
Agency Information
• UL Recognized: E19180
• CSA: 42731
Part Number System/Ordering - An Option Code Must Be Selected
• Specify packaging code prefix, product and option code suffix
Packaging Code Prefix
Fuse Series
Amp Rating
Option Code Suffix
DC Application
BK PCB- 1/2 -R
The PC-Tron subminiature fuse is UL Recognized for DC supplementary
overcurrent protection to provide individual protection for components or
internal circuits in equipment. Suitability for a specific application is dependent
on time constants and capacitance values. It is the responsibility of the
customer to evaluate the information provided for applicability to their
particular application.
PCS Mounting Socket (RoHS compliant)
• Available as option. Specify catalog number BK/PCS (100 in a polybag)
and short fuse lead length — PCC or PCE
0.300"
(7.62mm)
0.200"
(5.08mm)
0.095"
(2.41mm)
0.030"
(2.41mm)
0.290"
(7.37mm)
0.12" 0.010"
(3.05mm 0.25mm)
Catalog Number
PCB-1/2, 3/4, 1, 1-1/2, 2, 2-1/2
PCB-3
PCB-4
PCC-1/2, 3/4, 1, 1-1/2, 2, 2-1/2
PCC-3
PCC-4
PCD-5
PCE-5
PCF-1/2, 3/4, 1, 1-1/2, 2, 2-1/2
PCF-3
PCG-5
PCH-1/2, 3/4, 1, 1-1/2, 2, 2-1/2
PCH-3
PCH-4
PCI-5
Lead
Length
Full - 0.750" (straight)
Full - 0.750" (straight)
Full - 0.750” (straight)
Short 0.100" (straight)
Short 0.100" (straight)
Short 0.100" (straight)
Full - 0.750" (straight)
Short 0.100" (straight)
0.475"
0.475"
0.475"
0.125"
0.125"
0.125"
0.125"
Specifications
AC Voltage
Rating
250V
250V
-
250V
250V
-
125V
125V
250V
250V
125V
250V
250V
-
125V
AC
Interrupting
50A@250V - 10kA@125V
50A@250V
-
50A@250V - 10kA@125V
50A@250V - 10kA@125V
-
10kA@125V
10kA@125V
50A@250V - 10kA@125V
50A@250V - 10kA@125V
10kA@125V
50A@250V - 10kA@125V
50A@250V - 10kA@125V
-
10kA@125V
DC Voltage
Rating
450V
450V
450V
450V
450V
450V
400V
400V
450V
450V
400V
450V
450V
450V
400V
DC Interrupting
Min.
Max.
300
5900A
300
4400A
300
2500A
300
5900A
300
4400A
300
2500A
300
1000A
300
1000A
300
5900A
300
4400A
300
1000A
300
5900A
300
4400A
300
2500A
300
1000A
Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at elevated
ambient temperatures.
0211 BU-SB11083
Page 1 of 2
Data Sheet 2034