English
Language : 

HEJ Datasheet, PDF (1/1 Pages) Cooper Bussmann, Inc. – TRON® In-Line Fuseholders
TRON® In-Line Fuseholders
Single-Pole for SC-35 – 60A and HVW Fuses
Bussmann®
HEJ
Series
Non-Breakaway Holders
HEJ Series Catalog Symbol: HEJ-AA(1) (2) (3), HEJ-AB,
HEJ-AC, HEJ-BB, HEJ-CC, HEJ-DD, HEJ-JJ, HEJ-JK,
HEJ-LL, HEJ-PP, and HEJ-QQ
In-Line Fuseholders, Single-Pole
Water-Resistant
Agency Information:
(1)UL Recognized, Guide IZLT2, File E14853
(2)CSA Certified, Class 6225-01, File 47235
(3)CE
HEJ — For SC fuses; 35A to 60A and high voltage fuses.
Type HVW, ⁄Ω™ to 6A, 1200Vac (or less).
Fuse size ⁄‹Ω£™∑ ≈ 2⁄Ω¢∑. Holder rated 60A, 480V
Example:
A single-pole, in-line holder for a SC-40 fuse. A single #8
copper, stranded wire is on the load. Copper crimp connec-
tion desired. Two #10 copper, stranded wires are on the line
side. Copper crimp is the desired connection.
1. Choose HEJ- series.
2. Choose “A” for load side.
3. Choose “B” for line side.
Complete Part Number: HEJ-AB
Catalog and Specification Data
Conductor Terminals
Conductor Data
Terminal Type
Size
Catalog
Symbol
Load &
Line
Copper Crimp
Copper Set-Screw
#12 to #8
1
•
•
A
#12
2
•
•
#10
2
•
•
#6
1
•
•
B
#4
1
•
•
#8
2
•
•
C
#4
1
—•
#6
2
•
•
D
#2
1
—•
#12 to #3
1
•
•
J
#12 to #2
2
•
•
K
Aluminum Crimp
Aluminum Set-Screw
#6
#4
#3, #4
#2
1
—•
P
1
•—
1
—•
Q
1
•—
#12 to #2
1
•
•
L
Ordering Information:
HEJ
Load
Terminal
Line
Terminal
Recommended Torque on Coupling Nut: 10-20 in-lb.
Catalog Data — Insulating Boots
Catalog
Numbers
2A0660
2A0661
Type
Single Conductor
Two Conductor
Insulating boots are not included with non-breakaway parts
and must be ordered separately. They come standard with the
breakaway series. When boots are utilized, extra heat retention
requires that fuses are sized at a minimum of 200% of the
RMS load current.
The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is
intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change
design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information con-
tained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
7-16-03
N03082
Form No. HEJ Series
Page 1 of 1
Data Sheet: 2123