English
Language : 

HCP0704 Datasheet, PDF (1/4 Pages) Cooper Bussmann, Inc. – High Current, High Frequency, Power Inductors
High Current, High Frequency, Power Inductors
HCP0704 Series
SMD Device
Description:
• Halogen free
• 155°C maximum total temperature operation
• 6.8 x 6.8 x 4.2mm surface mount package
• Powder iron core material
• Magnetically shielded, low EMI
• High temperature core material eliminates thermal aging issues
• High current carrying capacity, low core losses
• Controlled DCR tolerance for sensing circuits
• Inductance range from 0.40μH to 4.7μH
• Current range from 5.0 to 27 amps
• Frequency range up to 2MHz
• RoHS compliant
Applications:
• Voltage Regulator Module (VRM)
• Multi-phase regulators
• Desktop and servers
• Base station equipment
• Notebook regulators
• Data networking and storage systems
• Point-of-load modules
• Battery power systems
• DCR sensing
HALOGEN
HF
FREE
Environmental Data:
• Storage temperature range: -40°C to +155°C
• Operating temperature range: -40°C to +155°C
(Range is application specific)
• Solder reflow temperature: J-STD-020D compliant
Packaging:
• Supplied in tape-and-reel packaging, 1000 parts per reel,
13” diameter reel
Part Number6
HCP0704-R40-R
HCP0704-R60-R
HCP0704-1R0-R
HCP0704-1R8-R
HCP0704-2R3-R
HCP0704-3R3-R
HCP0704-4R7-R
OCL1 ± 25% (μH)
0.40
0.60
1.00
1.80
2.30
3.30
4.70
Product Specifications
FLL2 Min. (μH)
Irms3 (Amps) Isat4 @ 25°C (Amps)
0.28
17
27
0.42
14
21
0.7
12
17
1.26
8.5
13
1.56
7.5
11.5
2.31
6.0
9.5
3.29
5.0
8.0
DCR (mΩ) @ 20°C
3.2 ±10%
4.5 ±10%
6.2 ±10%
11.0 ±10%
16.5 ±10%
25.0 ±10%
29.5 ±10%
K-factor5
383.1
313.5
265.3
202.8
164.2
149.9
127.7
1 Open Circuit Inductance (OCL) Test Parameters: 100kHz, 0.10Vrms, 0.0Adc
2 Full Load Inductance (FLL) Test Parameters: 100kHz, 0.1Vrms, Isat1
3 Irms: DC current for an approximate temperature rise of 40°C without core loss. Derating is
necessary for AC currents. PCB pad layout, trace thickness and width, air-flow and proximity of
other heat generating components will affect the temperature rise. It is recommended the part
temperature not exceed 155°C under worst case operating conditions verified in the end
application.
4 Isat: Peak current for approximately 20% rolloff at +25°C.
5 K-factor: Used to determine Bp-p for core loss (see graph). Bp-p = K * L * ΔI : (Gauss), K: (K-factor
from table), L: (inductance in μH), ΔI (peak-to-peak ripple current in amps).
6 Part Number Definition: HCP0704-xxx-R
• HCP0704 = Product code and size
• xxx= Inductance value in μH, R = decimal point. If no “R” is present, then
third character = # of zeros
• “-R” suffix = RoHS compliant
0209 BU-SB09086
Page 1 of 4
Data Sheet: 4348