English
Language : 

GDA-50MA Datasheet, PDF (1/2 Pages) Cooper Bussmann, Inc. – GDA Series, Fast-Acting, Ceramic Tube
5 x 20mm Fuses
GDA Series, Fast-Acting, Ceramic Tube
Description
• Fast-acting, high breaking capacity
• 5 x 20mm physical size
• Ceramic tube, nickel-plated brass endcap construction
• Silver-plated endcap construction (50mA-400mA)
• Optional axial leads are 0.032" x 1.5" copper tinned
• Designed to IEC 60127-2
In
50mA-3.15A
4A-10A
Electrical Characteristics
1.5 In 2.1 In 2.75 In
4 In
min max min max min max
60 min 30 min 10 ms 2 sec 3 ms 300 ms
60 min 30 min 10 ms 3 sec 3 ms 300 ms
10 In
max
20 ms
20 ms
Agency Information
• UL Recognized Card: Guide JDYX2, File E19180
• CSA Component Acceptance: File 53787
• Semko Approval: File 413779, File 512433
• IMQ Approval: File EB405
• CCC: File 2005010207155691
Ordering
Specify product code
• Insert packaging code prefix before part number. E.g.
BK/GDA-250mA
Specify option code if desired
• For axial leads, insert “V” between catalog series and
amp rating. E.g. BK/GDA-V-250mA
Dimensions - mm
Drawing Not to Scale
• With TR2 packaging code, lead wire length is 19.05mm
Specifications
Voltage Interrupting Rating (amps) Typical DC Typical Typical
Part Number Rating at Rated Voltage (50Hz) Cold Resistance Melting I2t Voltage IMQ
Vac
Vac
(Ω)*
(amps) Drop (mV)‡
GDA-50mA 250
1500
157.5
0.0017
9000
X
GDA-63mA 250
1500
39.0
0.0005
3300
GDA-80mA 250
1500
27.9
0.0011
2600
GDA-100mA 250
1500
20.0
0.0018
2300
GDA-125mA 250
1500
12.3
0.0037
1900
GDA-160mA 250
1500
8.5
0.008
1600
X
GDA-200mA 250
1500
6.0
0.020
1350
X
GDA-250mA 250
1500
4.4
0.027
1300
X
GDA-315mA 250
1500
3.3
0.010
1400
X
GDA-400mA 250
1500
2.2
0.018
1200
GDA-500mA 250
1500
0.460
0.038
1050
X
GDA-630mA 250
1500
0.340
0.064
1200
GDA-800mA 250
1500
0.245
0.097
490
X
GDA-1A
250
1500
0.231
0.146*
330
GDA-1.25A
250
1500
0.176
0.313*
297
GDA-1.6A
250
1500
0.113
0.748*
239
GDA-2A
250
1500
0.073
2.0
205
X
GDA-2.5A
250
1500
0.053
3.9
190
X
GDA-3.15A
250
1500
0.037
8.1
160
X
GDA-4A
250
1500
0.027
14
160
X
GDA-5A
250
1500
0.019
25
155
X
GDA-6.3A
250
1500
0.014
48
150
X
‡ Typical Voltage Drop (Voltage drop was measured at 20ºC ambient temperature at rated current)
*I2t of 1A, 1.25A, 1.6A is measured at 10In DC.
**CSA Approvals on these ratings will not be marked on the fuse cap.
Agency Approvals
SEMKO UR
CCC
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
CSA
X
X
X
X
X
X
X
X
X
X
X
X
X**
X**
X**
X**
X**
X
0209 BU-SB08725
Page 1 of 2
Data Sheet 2014