English
Language : 

FP1006R1-R08-R Datasheet, PDF (1/4 Pages) Cooper Bussmann, Inc. – High Current, High Frequency, Low-Profile Power Inductors
High Current, High Frequency, Low-Profile Power Inductors
FLAT-PAC™ FP1006 Series
SMD Device
Description
• Halogen free
• 125°C maximum total temperature operation
• 10.2 x 8.0 x 6.0mm surface mount package
• Ferrite core material
• High current carrying capacity, Low core losses
• Controlled DCR tolerance for sensing circuits
• Inductance range from 85nH to 220nH
• Current range from 38 to 100 amps
• Frequency range up to 2MHz
• RoHS compliant
Applications
• Multi-phase regulators
• Voltage Regulator Module (VRM)
• Point-of-load modules
• Desktop and server VRMs and EVRDs
• Data networking and storage systems
• Notebook regulators
• Graphics cards and battery power systems
• DCR sensing
Environmental Data
• Storage temperature range: -40°C to +125°C
• Operating temperature range: -40°C to +125°C
(Range is application specific)
• Solder reflow temperature: J-STD-020D compliant
Packaging
• Supplied in tape and reel packaging, 850 parts per reel,
13” diameter reel
Part Number7
R1 Version
FP1006R1-R08-R
FP1006R1-R10-R
FP1006R1-R12-R
FP1006R1-R16-R
FP1006R1-R22-R
R2 Version
FP1006R2-R08-R
FP1006R2-R10-R
FP1006R2-R12-R
FP1006R2-R16-R
FP1006R2-R22-R
Product Specifications
OCL1 ± 10% (nH) FLL2 Min. (nH) Irms3 (Amps) Isat14 @ 25°C (Amps) Isat25 @ 125°C (Amps) DCR (mΩ) @ 20°C K-factor6
85
61
100
100
72
85
120
86
53
71
160
115
55
220
158
38
70
454
64
454
53
0.27 ± 12%
454
40
454
28
454
85
61
100
100
72
85
120
86
45
71
160
115
55
220
158
38
70
454
64
454
53
0.36 ± 8.6%
454
40
454
28
454
1 Open Circuit Inductance (OCL) Test Parameters: 100kHz, 0.10Vrms, 0.0Adc
2 Full Load Inductance (FLL) Test Parameters: 100kHz, 0.1Vrms, Isat1
3 Irms: DC current for an approximate temperature rise of 40°C without core loss. Derating is
necessary for AC currents. PCB pad layout, trace thickness and width, air-flow and proximity of
other heat generating components will affect the temperature rise. It is recommended the part
temperature not exceed 125°C under worst case operating conditions verified in the end
application.
4 Isat1: Peak current for approximately 20% rolloff at +25°C.
5 Isat2: Peak current for approximately 20% rolloff at +125°C.
6 K-factor: Used to determine Bp-p for core loss (see graph). Bp-p = K * L * ΔI * 10-3, Bp-p : (Gauss),
K: (K-factor from table), L: (inductance in nH), ΔI (peak-to-peak ripple current in amps).
7 Part Number Definition: FP1006Rx-Rxx-R
• FP1006 = Product code and size
• Rx is the DCR indicator
• Rxx= Inductance value in μH, R = decimal point • “-R” suffix = RoHS compliant
1208 BU-SB08861
Page 1 of 4
Data Sheet: 4338